Thermal analysis of H.V. insulation oil during partial discharge detection

Historically, the arc discharge analyzing technique was one of the first methods to determine the status of the insulation oil. Due to the harsh environment and the continue usage of the high voltage transformers, many problems of insulation can be produced leading to the failure of the transformer....

Full description

Saved in:
Bibliographic Details
Main Author: Gatea, Rasool Abdelfadil
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/48751/1/RasoolAbdelfadilGateaMFKE2014.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.48751
record_format uketd_dc
spelling my-utm-ep.487512020-06-21T06:53:03Z Thermal analysis of H.V. insulation oil during partial discharge detection 2014-12 Gatea, Rasool Abdelfadil TK Electrical engineering. Electronics Nuclear engineering Historically, the arc discharge analyzing technique was one of the first methods to determine the status of the insulation oil. Due to the harsh environment and the continue usage of the high voltage transformers, many problems of insulation can be produced leading to the failure of the transformer. The problem of the thesis is to find the best available solution to conduct real time analyzing of insulation oil of high voltage transformers, so that the high voltage transformer can be safeguarded from failure in the most effective and economic manner. In this work, the temperature of the insulation oil will be captured and calculated with and without partial discharge occurring. The simulated arc discharge is generated using 7.5 kV power source in two round shape steel electrodes having 5 mm gap. This distance (between the sensor and arc discharge source) is set at 5 cm. The infrared thermometer (laser gun) was used to capture the insulation oil temperature by sending a laser light toward the insulation oil and that light will be reflected beck and received by the device and then the temperature of the oil will be captured and measured. This study will help to predict the insulation oil age of high voltage transformers, which reduce the maintenance cost of high voltage transformer. 2014-12 Thesis http://eprints.utm.my/id/eprint/48751/ http://eprints.utm.my/id/eprint/48751/1/RasoolAbdelfadilGateaMFKE2014.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:85997 masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Gatea, Rasool Abdelfadil
Thermal analysis of H.V. insulation oil during partial discharge detection
description Historically, the arc discharge analyzing technique was one of the first methods to determine the status of the insulation oil. Due to the harsh environment and the continue usage of the high voltage transformers, many problems of insulation can be produced leading to the failure of the transformer. The problem of the thesis is to find the best available solution to conduct real time analyzing of insulation oil of high voltage transformers, so that the high voltage transformer can be safeguarded from failure in the most effective and economic manner. In this work, the temperature of the insulation oil will be captured and calculated with and without partial discharge occurring. The simulated arc discharge is generated using 7.5 kV power source in two round shape steel electrodes having 5 mm gap. This distance (between the sensor and arc discharge source) is set at 5 cm. The infrared thermometer (laser gun) was used to capture the insulation oil temperature by sending a laser light toward the insulation oil and that light will be reflected beck and received by the device and then the temperature of the oil will be captured and measured. This study will help to predict the insulation oil age of high voltage transformers, which reduce the maintenance cost of high voltage transformer.
format Thesis
qualification_level Master's degree
author Gatea, Rasool Abdelfadil
author_facet Gatea, Rasool Abdelfadil
author_sort Gatea, Rasool Abdelfadil
title Thermal analysis of H.V. insulation oil during partial discharge detection
title_short Thermal analysis of H.V. insulation oil during partial discharge detection
title_full Thermal analysis of H.V. insulation oil during partial discharge detection
title_fullStr Thermal analysis of H.V. insulation oil during partial discharge detection
title_full_unstemmed Thermal analysis of H.V. insulation oil during partial discharge detection
title_sort thermal analysis of h.v. insulation oil during partial discharge detection
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2014
url http://eprints.utm.my/id/eprint/48751/1/RasoolAbdelfadilGateaMFKE2014.pdf
_version_ 1747817466925416448