Signal interference to electroencephalogram and electrocardiogram signal

The increment in a number of electric and electronic devices nowadays ignites the curiosity about the effect of Electromagnetic Interference (EMI) coming from those devices especially in medical environment. In general, the probability for EMI incidents to occur is small. However, the effect from th...

Full description

Saved in:
Bibliographic Details
Main Author: Abdul Samad, Noraini
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/50677/25/NorainiAbdulSamadMFKE2015.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.50677
record_format uketd_dc
spelling my-utm-ep.506772017-06-06T07:31:32Z Signal interference to electroencephalogram and electrocardiogram signal 2015-02 Abdul Samad, Noraini TK Electrical engineering. Electronics Nuclear engineering The increment in a number of electric and electronic devices nowadays ignites the curiosity about the effect of Electromagnetic Interference (EMI) coming from those devices especially in medical environment. In general, the probability for EMI incidents to occur is small. However, the effect from the incident could lead to a very fatal and hazardous side effect. This study strictly focuses on the effect of electromagnetic interference from medical devices that are placed close to the electrocardiogram (ECG) and electroencephalogram (EEG) devices during ECG and EEG signal acquisitions. Since both ECG and EEG machine are most crucial equipments to examine critical part of human body, the devices should be handled with extra precaution towards EMI contamination. An analysis was carried out by using the Fast Fourier Transform (FFT) and QRS Wave Peak Detection to study the effect of EMI from several types of medical devices on both ECG and EEG signals. The result of analysis on the signal exposed to the interference from medical devices was compared to the signal obtained in environment without medical devices.The results showed that interference from blood pressure cuff, electroglotograph, ultrasound, microspirometer and electro muscle stimulator disturbed the quality of signal displayed as well as the amplitude and frequency component of the ECG and EEG signals at 0 cm distance. Even though the EMI can be easily filtered out by using highpass and lowpass filter, the noise can be misinterpreted as a symptom of arrhythmia and consequently leads to unnecessary treatment and panic situation on medical staff. 2015-02 Thesis http://eprints.utm.my/id/eprint/50677/ http://eprints.utm.my/id/eprint/50677/25/NorainiAbdulSamadMFKE2015.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Abdul Samad, Noraini
Signal interference to electroencephalogram and electrocardiogram signal
description The increment in a number of electric and electronic devices nowadays ignites the curiosity about the effect of Electromagnetic Interference (EMI) coming from those devices especially in medical environment. In general, the probability for EMI incidents to occur is small. However, the effect from the incident could lead to a very fatal and hazardous side effect. This study strictly focuses on the effect of electromagnetic interference from medical devices that are placed close to the electrocardiogram (ECG) and electroencephalogram (EEG) devices during ECG and EEG signal acquisitions. Since both ECG and EEG machine are most crucial equipments to examine critical part of human body, the devices should be handled with extra precaution towards EMI contamination. An analysis was carried out by using the Fast Fourier Transform (FFT) and QRS Wave Peak Detection to study the effect of EMI from several types of medical devices on both ECG and EEG signals. The result of analysis on the signal exposed to the interference from medical devices was compared to the signal obtained in environment without medical devices.The results showed that interference from blood pressure cuff, electroglotograph, ultrasound, microspirometer and electro muscle stimulator disturbed the quality of signal displayed as well as the amplitude and frequency component of the ECG and EEG signals at 0 cm distance. Even though the EMI can be easily filtered out by using highpass and lowpass filter, the noise can be misinterpreted as a symptom of arrhythmia and consequently leads to unnecessary treatment and panic situation on medical staff.
format Thesis
qualification_level Master's degree
author Abdul Samad, Noraini
author_facet Abdul Samad, Noraini
author_sort Abdul Samad, Noraini
title Signal interference to electroencephalogram and electrocardiogram signal
title_short Signal interference to electroencephalogram and electrocardiogram signal
title_full Signal interference to electroencephalogram and electrocardiogram signal
title_fullStr Signal interference to electroencephalogram and electrocardiogram signal
title_full_unstemmed Signal interference to electroencephalogram and electrocardiogram signal
title_sort signal interference to electroencephalogram and electrocardiogram signal
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2015
url http://eprints.utm.my/id/eprint/50677/25/NorainiAbdulSamadMFKE2015.pdf
_version_ 1747817509457756160