Testing of metal oxide surge arrester monitoring (MOSAM)

Surge arrester is a device used to protect the transmission lines and substations. It protects the power systems from lightning impulses and very fast transient over voltage. The degradation of a metal oxide surge arrester can be accomplished by using the measurement of its leakage current in partic...

Full description

Saved in:
Bibliographic Details
Main Author: Zainol, Zuraida
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/50682/25/ZuraidaZainolMFKE2015.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.50682
record_format uketd_dc
spelling my-utm-ep.506822020-07-08T04:00:51Z Testing of metal oxide surge arrester monitoring (MOSAM) 2015-01 Zainol, Zuraida TK Electrical engineering. Electronics Nuclear engineering Surge arrester is a device used to protect the transmission lines and substations. It protects the power systems from lightning impulses and very fast transient over voltage. The degradation of a metal oxide surge arrester can be accomplished by using the measurement of its leakage current in particular, the third harmonic resistive component. A significant change in the third harmonic level may indicate a severe ageing of the arrester. Metal Oxide Surge Arrester Monitoring (MOSAM) is a new smartphone based device capable of assessing the current status of gapless MO arresters. This project aims to test and verify the MOSAM previously developed in Institute of High Voltage and High Current (IVAT). Low voltage and high voltage calibration were carried out. It is shown that the obtained calibration results using the low voltage are consistent with those using the high voltage. Three types of clamp meters were used. MOSAM is proven to work as designed for at least one type of clamp meter. 2015-01 Thesis http://eprints.utm.my/id/eprint/50682/ http://eprints.utm.my/id/eprint/50682/25/ZuraidaZainolMFKE2015.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:85039 masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Zainol, Zuraida
Testing of metal oxide surge arrester monitoring (MOSAM)
description Surge arrester is a device used to protect the transmission lines and substations. It protects the power systems from lightning impulses and very fast transient over voltage. The degradation of a metal oxide surge arrester can be accomplished by using the measurement of its leakage current in particular, the third harmonic resistive component. A significant change in the third harmonic level may indicate a severe ageing of the arrester. Metal Oxide Surge Arrester Monitoring (MOSAM) is a new smartphone based device capable of assessing the current status of gapless MO arresters. This project aims to test and verify the MOSAM previously developed in Institute of High Voltage and High Current (IVAT). Low voltage and high voltage calibration were carried out. It is shown that the obtained calibration results using the low voltage are consistent with those using the high voltage. Three types of clamp meters were used. MOSAM is proven to work as designed for at least one type of clamp meter.
format Thesis
qualification_level Master's degree
author Zainol, Zuraida
author_facet Zainol, Zuraida
author_sort Zainol, Zuraida
title Testing of metal oxide surge arrester monitoring (MOSAM)
title_short Testing of metal oxide surge arrester monitoring (MOSAM)
title_full Testing of metal oxide surge arrester monitoring (MOSAM)
title_fullStr Testing of metal oxide surge arrester monitoring (MOSAM)
title_full_unstemmed Testing of metal oxide surge arrester monitoring (MOSAM)
title_sort testing of metal oxide surge arrester monitoring (mosam)
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2015
url http://eprints.utm.my/id/eprint/50682/25/ZuraidaZainolMFKE2015.pdf
_version_ 1747817510695075840