Lubrication effect of metal-on-metal in hip joint replacement

The use of hard-on-hard material is one of alternative methods to replace the soft-on-soft or soft-on-hard material which has long been used in hip joint replacement. The common type of hard-on-hard material used in hip joint replacement is metal-on-metal. However, the metal-on-metal hip implants pr...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd. Suri, Mohd. Syafiq
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/50823/25/MohdSyafiqMohdSuriMFKM2014.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.50823
record_format uketd_dc
spelling my-utm-ep.508232020-07-13T01:10:39Z Lubrication effect of metal-on-metal in hip joint replacement 2014-05 Mohd. Suri, Mohd. Syafiq TJ Mechanical engineering and machinery The use of hard-on-hard material is one of alternative methods to replace the soft-on-soft or soft-on-hard material which has long been used in hip joint replacement. The common type of hard-on-hard material used in hip joint replacement is metal-on-metal. However, the metal-on-metal hip implants produce the small wear particle as a result of attrition of the contact surface between femoral head and acetabulum cup. Therefore, the lubrication performance between the surface of the femoral head and acetabulum cup is essential to reduce wear particle. The objective of this study was to determine the effect of lubrication on metal-on-metal hip joint replacement. Two types of contact analysis were performed, without and with lubrication. In the contact analysis of without lubrication, the maximum contact pressure was 32.887 MPa while lubrication contact analysis, maximum contact pressure was lower. It was occurred because between the surface of femoral head and acetabulum cup has full fluid film lubrication. This causes the wear that produced by metal-on-metal hip joint implants can be reduced because an effective lubricant film is able to reduce wear significantly. In addition, this study focused on the design parameters, radial clearance and femoral head size. It was found that the maximum contact pressure increased when the radial clearance also increased and the maximum contact pressure decreased when the femoral head size increased. 2014-05 Thesis http://eprints.utm.my/id/eprint/50823/ http://eprints.utm.my/id/eprint/50823/25/MohdSyafiqMohdSuriMFKM2014.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:94785 masters Universiti Teknologi Malaysia, Faculty of Mechanical Engineering Faculty of Mechanical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Mohd. Suri, Mohd. Syafiq
Lubrication effect of metal-on-metal in hip joint replacement
description The use of hard-on-hard material is one of alternative methods to replace the soft-on-soft or soft-on-hard material which has long been used in hip joint replacement. The common type of hard-on-hard material used in hip joint replacement is metal-on-metal. However, the metal-on-metal hip implants produce the small wear particle as a result of attrition of the contact surface between femoral head and acetabulum cup. Therefore, the lubrication performance between the surface of the femoral head and acetabulum cup is essential to reduce wear particle. The objective of this study was to determine the effect of lubrication on metal-on-metal hip joint replacement. Two types of contact analysis were performed, without and with lubrication. In the contact analysis of without lubrication, the maximum contact pressure was 32.887 MPa while lubrication contact analysis, maximum contact pressure was lower. It was occurred because between the surface of femoral head and acetabulum cup has full fluid film lubrication. This causes the wear that produced by metal-on-metal hip joint implants can be reduced because an effective lubricant film is able to reduce wear significantly. In addition, this study focused on the design parameters, radial clearance and femoral head size. It was found that the maximum contact pressure increased when the radial clearance also increased and the maximum contact pressure decreased when the femoral head size increased.
format Thesis
qualification_level Master's degree
author Mohd. Suri, Mohd. Syafiq
author_facet Mohd. Suri, Mohd. Syafiq
author_sort Mohd. Suri, Mohd. Syafiq
title Lubrication effect of metal-on-metal in hip joint replacement
title_short Lubrication effect of metal-on-metal in hip joint replacement
title_full Lubrication effect of metal-on-metal in hip joint replacement
title_fullStr Lubrication effect of metal-on-metal in hip joint replacement
title_full_unstemmed Lubrication effect of metal-on-metal in hip joint replacement
title_sort lubrication effect of metal-on-metal in hip joint replacement
granting_institution Universiti Teknologi Malaysia, Faculty of Mechanical Engineering
granting_department Faculty of Mechanical Engineering
publishDate 2014
url http://eprints.utm.my/id/eprint/50823/25/MohdSyafiqMohdSuriMFKM2014.pdf
_version_ 1747817542500483072