Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection

Most connections that fasten beams to columns are deformable and exhibit a non-linear behaviour between conditions fully fixed and perfectly pinned. Connection flexibility affects both force distribution and deformation in beams and columns of the frame and must be accounted for in a structural anal...

Full description

Saved in:
Bibliographic Details
Main Author: Ahmad, Che Husni
Format: Thesis
Language:English
Published: 2005
Subjects:
Online Access:http://eprints.utm.my/id/eprint/5293/1/CheHusniAhmadMFKA2005.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.5293
record_format uketd_dc
spelling my-utm-ep.52932018-02-28T08:21:03Z Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection 2005-11 Ahmad, Che Husni TA Engineering (General). Civil engineering (General) Most connections that fasten beams to columns are deformable and exhibit a non-linear behaviour between conditions fully fixed and perfectly pinned. Connection flexibility affects both force distribution and deformation in beams and columns of the frame and must be accounted for in a structural analysis. This problem can be solved by conducting a non-linear analysis, which addresses both the geometric non-linearity and connection flexibility. The linear elastic analysis assumes that the deformations are relatively small and the equilibrium equations can be formulated with respect to initial geometry. To see the differences between the above approaches on moment capacity of the connection, a model of A Symmetric Flush End Plate Bolted Beam-to-Column connection model has been analysed using both approaches above. This model will be made similar to the model that had an experimental data for verification. From non-linear computer analysis the moment capacity model is found to be 7.8 kNm compared to experimental data, 8.8 kNm. The moment capacity resulted from linear analysis is found to be 19.5 kNm which is 2.5 time the non-linear analysis result or 2.216 above the experimental data. The results of this study shows an agreement with previous researchers that the connection behaves in between pinne d and fully rigid and possess some rotational stiffness. 2005-11 Thesis http://eprints.utm.my/id/eprint/5293/ http://eprints.utm.my/id/eprint/5293/1/CheHusniAhmadMFKA2005.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Ahmad, Che Husni
Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
description Most connections that fasten beams to columns are deformable and exhibit a non-linear behaviour between conditions fully fixed and perfectly pinned. Connection flexibility affects both force distribution and deformation in beams and columns of the frame and must be accounted for in a structural analysis. This problem can be solved by conducting a non-linear analysis, which addresses both the geometric non-linearity and connection flexibility. The linear elastic analysis assumes that the deformations are relatively small and the equilibrium equations can be formulated with respect to initial geometry. To see the differences between the above approaches on moment capacity of the connection, a model of A Symmetric Flush End Plate Bolted Beam-to-Column connection model has been analysed using both approaches above. This model will be made similar to the model that had an experimental data for verification. From non-linear computer analysis the moment capacity model is found to be 7.8 kNm compared to experimental data, 8.8 kNm. The moment capacity resulted from linear analysis is found to be 19.5 kNm which is 2.5 time the non-linear analysis result or 2.216 above the experimental data. The results of this study shows an agreement with previous researchers that the connection behaves in between pinne d and fully rigid and possess some rotational stiffness.
format Thesis
qualification_level Master's degree
author Ahmad, Che Husni
author_facet Ahmad, Che Husni
author_sort Ahmad, Che Husni
title Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
title_short Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
title_full Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
title_fullStr Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
title_full_unstemmed Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
title_sort non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
granting_institution Universiti Teknologi Malaysia, Faculty of Civil Engineering
granting_department Faculty of Civil Engineering
publishDate 2005
url http://eprints.utm.my/id/eprint/5293/1/CheHusniAhmadMFKA2005.pdf