Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection
Most connections that fasten beams to columns are deformable and exhibit a non-linear behaviour between conditions fully fixed and perfectly pinned. Connection flexibility affects both force distribution and deformation in beams and columns of the frame and must be accounted for in a structural anal...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2005
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/5293/1/CheHusniAhmadMFKA2005.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-utm-ep.5293 |
---|---|
record_format |
uketd_dc |
spelling |
my-utm-ep.52932018-02-28T08:21:03Z Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection 2005-11 Ahmad, Che Husni TA Engineering (General). Civil engineering (General) Most connections that fasten beams to columns are deformable and exhibit a non-linear behaviour between conditions fully fixed and perfectly pinned. Connection flexibility affects both force distribution and deformation in beams and columns of the frame and must be accounted for in a structural analysis. This problem can be solved by conducting a non-linear analysis, which addresses both the geometric non-linearity and connection flexibility. The linear elastic analysis assumes that the deformations are relatively small and the equilibrium equations can be formulated with respect to initial geometry. To see the differences between the above approaches on moment capacity of the connection, a model of A Symmetric Flush End Plate Bolted Beam-to-Column connection model has been analysed using both approaches above. This model will be made similar to the model that had an experimental data for verification. From non-linear computer analysis the moment capacity model is found to be 7.8 kNm compared to experimental data, 8.8 kNm. The moment capacity resulted from linear analysis is found to be 19.5 kNm which is 2.5 time the non-linear analysis result or 2.216 above the experimental data. The results of this study shows an agreement with previous researchers that the connection behaves in between pinne d and fully rigid and possess some rotational stiffness. 2005-11 Thesis http://eprints.utm.my/id/eprint/5293/ http://eprints.utm.my/id/eprint/5293/1/CheHusniAhmadMFKA2005.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering |
institution |
Universiti Teknologi Malaysia |
collection |
UTM Institutional Repository |
language |
English |
topic |
TA Engineering (General) Civil engineering (General) |
spellingShingle |
TA Engineering (General) Civil engineering (General) Ahmad, Che Husni Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection |
description |
Most connections that fasten beams to columns are deformable and exhibit a non-linear behaviour between conditions fully fixed and perfectly pinned. Connection flexibility affects both force distribution and deformation in beams and columns of the frame and must be accounted for in a structural analysis. This problem can be solved by conducting a non-linear analysis, which addresses both the geometric non-linearity and connection flexibility. The linear elastic analysis assumes that the deformations are relatively small and the equilibrium equations can be formulated with respect to initial geometry. To see the differences between the above approaches on moment capacity of the connection, a model of A Symmetric Flush End Plate Bolted Beam-to-Column connection model has been analysed using both approaches above. This model will be made similar to the model that had an experimental data for verification. From non-linear computer analysis the moment capacity model is found to be
7.8 kNm compared to experimental data, 8.8 kNm. The moment capacity resulted from linear analysis is found to be 19.5 kNm which is 2.5 time the non-linear analysis result or 2.216 above the experimental data.
The results of this study shows an agreement with previous researchers that
the connection behaves in between pinne
d and fully rigid and possess some
rotational stiffness. |
format |
Thesis |
qualification_level |
Master's degree |
author |
Ahmad, Che Husni |
author_facet |
Ahmad, Che Husni |
author_sort |
Ahmad, Che Husni |
title |
Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection |
title_short |
Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection |
title_full |
Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection |
title_fullStr |
Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection |
title_full_unstemmed |
Non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection |
title_sort |
non-linear analysis of a symmetric flush end plate bolted beam-to-column steel connection |
granting_institution |
Universiti Teknologi Malaysia, Faculty of Civil Engineering |
granting_department |
Faculty of Civil Engineering |
publishDate |
2005 |
url |
http://eprints.utm.my/id/eprint/5293/1/CheHusniAhmadMFKA2005.pdf |
_version_ |
1747814572939542528 |