Outrigger system for interconnecting three dimensional multi-stories buildings

In tall buildings design, lateral loads induced by wind or earthquake forces are often resisted by an outrigger system. This system is often chosen as its function by tying the structural components together to provide sufficient lateral stiffness to the structure and control the excessive drift due...

Full description

Saved in:
Bibliographic Details
Main Author: Teck Shin, Lee
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/53457/25/LeeTeckShinMFKA2014.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.53457
record_format uketd_dc
spelling my-utm-ep.534572020-07-15T03:25:23Z Outrigger system for interconnecting three dimensional multi-stories buildings 2014-06 Teck Shin, Lee TH Building construction In tall buildings design, lateral loads induced by wind or earthquake forces are often resisted by an outrigger system. This system is often chosen as its function by tying the structural components together to provide sufficient lateral stiffness to the structure and control the excessive drift due to the lateral load. This thesis is to analyze the behavior of two 30 stories residential buildings that interconnected by a link bridge which acted as an exterior outrigger system at different heights and also the outrigger system location optimization. A total of five models with different configuration of exterior outrigger system which interconnecting the two multi-stories buildings had been analyzed by using ETABS software program. There is one model with no outrigger system is applied, three models with outrigger system interconnected at different height locations which are level 10, level 20 and level 30 of the buildings respectively, and last model with outrigger system is applied at three levels which are level 10, 20 and 30. The modeling process was carried out in such a way that the behavior and performance of the structure was within the limitations suggested by BSI (2001) CP 3: Chapter V-2: 1972. From the results, the percentage of reduction in lateral displacement is directly proportional to the number of level of outrigger system applied to the multi-stories buildings. By comparison, it is structurally efficient to locate an exterior outrigger system at the top of a building. Study has shown that it is indeed helpful in reducing the lateral displacement of building structure by applying the outrigger system as an exterior structural system for interconnecting between the multi-stories buildings. 2014-06 Thesis http://eprints.utm.my/id/eprint/53457/ http://eprints.utm.my/id/eprint/53457/25/LeeTeckShinMFKA2014.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:86435 masters Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TH Building construction
spellingShingle TH Building construction
Teck Shin, Lee
Outrigger system for interconnecting three dimensional multi-stories buildings
description In tall buildings design, lateral loads induced by wind or earthquake forces are often resisted by an outrigger system. This system is often chosen as its function by tying the structural components together to provide sufficient lateral stiffness to the structure and control the excessive drift due to the lateral load. This thesis is to analyze the behavior of two 30 stories residential buildings that interconnected by a link bridge which acted as an exterior outrigger system at different heights and also the outrigger system location optimization. A total of five models with different configuration of exterior outrigger system which interconnecting the two multi-stories buildings had been analyzed by using ETABS software program. There is one model with no outrigger system is applied, three models with outrigger system interconnected at different height locations which are level 10, level 20 and level 30 of the buildings respectively, and last model with outrigger system is applied at three levels which are level 10, 20 and 30. The modeling process was carried out in such a way that the behavior and performance of the structure was within the limitations suggested by BSI (2001) CP 3: Chapter V-2: 1972. From the results, the percentage of reduction in lateral displacement is directly proportional to the number of level of outrigger system applied to the multi-stories buildings. By comparison, it is structurally efficient to locate an exterior outrigger system at the top of a building. Study has shown that it is indeed helpful in reducing the lateral displacement of building structure by applying the outrigger system as an exterior structural system for interconnecting between the multi-stories buildings.
format Thesis
qualification_level Master's degree
author Teck Shin, Lee
author_facet Teck Shin, Lee
author_sort Teck Shin, Lee
title Outrigger system for interconnecting three dimensional multi-stories buildings
title_short Outrigger system for interconnecting three dimensional multi-stories buildings
title_full Outrigger system for interconnecting three dimensional multi-stories buildings
title_fullStr Outrigger system for interconnecting three dimensional multi-stories buildings
title_full_unstemmed Outrigger system for interconnecting three dimensional multi-stories buildings
title_sort outrigger system for interconnecting three dimensional multi-stories buildings
granting_institution Universiti Teknologi Malaysia, Faculty of Civil Engineering
granting_department Faculty of Civil Engineering
publishDate 2014
url http://eprints.utm.my/id/eprint/53457/25/LeeTeckShinMFKA2014.pdf
_version_ 1747817559951933440