The assessment of tailor-made optical fibre subjected to ionizing radiation

The dosimetric properties of thermoluminescence (TL) dosimeter such as dose response, linearity, sensitivity, fading, minimum detectable dose (MDD), glow curve and reproducibility of optical fibres in comparison with TLD-100 (rod types) have been investigated. The samples used were Dummy Flat Fibre...

Full description

Saved in:
Bibliographic Details
Main Author: Che Omar, Siti Shuwaibah
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/54657/25/SitiShuwaibahCheOmarMFS2015.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.54657
record_format uketd_dc
spelling my-utm-ep.546572020-11-03T07:30:59Z The assessment of tailor-made optical fibre subjected to ionizing radiation 2015-02 Che Omar, Siti Shuwaibah QC Physics The dosimetric properties of thermoluminescence (TL) dosimeter such as dose response, linearity, sensitivity, fading, minimum detectable dose (MDD), glow curve and reproducibility of optical fibres in comparison with TLD-100 (rod types) have been investigated. The samples used were Dummy Flat Fibre (DFF), Flat Fibre (FF), Photonic Crystal Fibre (PCF), Multi Photonic Crystal Fibre (MPCF) of 2 mm and 220 µm diameter, Photosensitive Flat Fibre (PFF), Single Mode Optical Fibre (SMF), Germanium - doped (Ge), Erbium - doped (Er) and Aluminum doped Thulium (Al: Tm). The TL samples were placed in solid phantom and irradiated with 6, 9 and 12 MeV electrons beam with dose ranging from 1.0 Gy to 4.0 Gy by using linear accelerator (LINAC) machine. Investigations were also conducted for X - rays with mean energies of 30, 60 and 70 kV, and gamma rays (60Co) from 1.0 mGy up to 24.0 Gy. The glow curves were observed between 155 °C to 287 °C. The results of TL dosimeter subjected to 6, 9 and 12 MeV electrons clearly showed that PFF was superior in terms of TL response and sensitivity. This was followed by Ge, DFF, TLD-100, FF, PCF, Er, Al: Tm, MPCF 2 mm and MPCF 220 µm. For X-ray irradiation, the SMF showed 10 and 8 times more sensitive than TLD-100. The MDD obtained from optical fibres subjected to electron irradiation were between 0.53- 0.60 mGy for PFF, 0.78-0.81 mGy for TLD-100, 1.00-1.26 mGy for Ge and 1.44-1.64 mGy for DFF. The results showed that PFF and SMF have great potential to be considered as a radiation dosimeter. 2015-02 Thesis http://eprints.utm.my/id/eprint/54657/ http://eprints.utm.my/id/eprint/54657/25/SitiShuwaibahCheOmarMFS2015.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:86782 masters Universiti Teknologi Malaysia, Faculty of science Faculty of science
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic QC Physics
spellingShingle QC Physics
Che Omar, Siti Shuwaibah
The assessment of tailor-made optical fibre subjected to ionizing radiation
description The dosimetric properties of thermoluminescence (TL) dosimeter such as dose response, linearity, sensitivity, fading, minimum detectable dose (MDD), glow curve and reproducibility of optical fibres in comparison with TLD-100 (rod types) have been investigated. The samples used were Dummy Flat Fibre (DFF), Flat Fibre (FF), Photonic Crystal Fibre (PCF), Multi Photonic Crystal Fibre (MPCF) of 2 mm and 220 µm diameter, Photosensitive Flat Fibre (PFF), Single Mode Optical Fibre (SMF), Germanium - doped (Ge), Erbium - doped (Er) and Aluminum doped Thulium (Al: Tm). The TL samples were placed in solid phantom and irradiated with 6, 9 and 12 MeV electrons beam with dose ranging from 1.0 Gy to 4.0 Gy by using linear accelerator (LINAC) machine. Investigations were also conducted for X - rays with mean energies of 30, 60 and 70 kV, and gamma rays (60Co) from 1.0 mGy up to 24.0 Gy. The glow curves were observed between 155 °C to 287 °C. The results of TL dosimeter subjected to 6, 9 and 12 MeV electrons clearly showed that PFF was superior in terms of TL response and sensitivity. This was followed by Ge, DFF, TLD-100, FF, PCF, Er, Al: Tm, MPCF 2 mm and MPCF 220 µm. For X-ray irradiation, the SMF showed 10 and 8 times more sensitive than TLD-100. The MDD obtained from optical fibres subjected to electron irradiation were between 0.53- 0.60 mGy for PFF, 0.78-0.81 mGy for TLD-100, 1.00-1.26 mGy for Ge and 1.44-1.64 mGy for DFF. The results showed that PFF and SMF have great potential to be considered as a radiation dosimeter.
format Thesis
qualification_level Master's degree
author Che Omar, Siti Shuwaibah
author_facet Che Omar, Siti Shuwaibah
author_sort Che Omar, Siti Shuwaibah
title The assessment of tailor-made optical fibre subjected to ionizing radiation
title_short The assessment of tailor-made optical fibre subjected to ionizing radiation
title_full The assessment of tailor-made optical fibre subjected to ionizing radiation
title_fullStr The assessment of tailor-made optical fibre subjected to ionizing radiation
title_full_unstemmed The assessment of tailor-made optical fibre subjected to ionizing radiation
title_sort assessment of tailor-made optical fibre subjected to ionizing radiation
granting_institution Universiti Teknologi Malaysia, Faculty of science
granting_department Faculty of science
publishDate 2015
url http://eprints.utm.my/id/eprint/54657/25/SitiShuwaibahCheOmarMFS2015.pdf
_version_ 1747817698259107840