Platoon dispersion downstream of traffic signal
The potential benefits of studying platoon dispersion downstream of traffic signal are already known in traffic flow analysis, modelling and traffic engineering design. However, presently there is a lack of information on platoon dispersion on Malaysian roads. This study determines the arrival distr...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2007
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/6412/1/NordianaMashrosMFKA2007.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-utm-ep.6412 |
---|---|
record_format |
uketd_dc |
spelling |
my-utm-ep.64122018-08-26T04:45:29Z Platoon dispersion downstream of traffic signal 2007-07 Mashros, Nordiana HE Transportation and Communications TA Engineering (General). Civil engineering (General) The potential benefits of studying platoon dispersion downstream of traffic signal are already known in traffic flow analysis, modelling and traffic engineering design. However, presently there is a lack of information on platoon dispersion on Malaysian roads. This study determines the arrival distribution pattern downstream of traffic signal which includes vehicle headway, intra-platoon headway and inter-platoon headway. It also looked into the roadway characteristic that affects platoon dispersion. Data for more than 1000 vehicles were collected using video cameras to record traffic movement at Saleng, Kulai. Vehicle type and time were determined for each vehicle on a per lane basis during the morning peak and off peak hours at several consecutive points downstream of traffic signal for analysis. Four mathematical distribution models namely shifted negative exponential distribution, erlang distribution, schuhl distribution and double displaced negative exponential distribution were fitted to the actual distribution data. It was observed that vehicle headways follow the shifted negative exponential distribution with shift equals to 1.0s, the intra-platoon headways have normal distribution and inter-platoon headways do not fit to any of the tested distribution models under peak and off peak hours. The level of friction at this road section is of low friction. The values of platoon dispersion factor and travel time factor are 0.16 and 0.86 during peak hour and 0.22 and 0.82 during off peak hour. The values of smoothing factor under these conditions are 0.21 (peak hour) and 0.17 (off peak hour). The higher value of smoothing factor indicates that the vehicles are able to travel on the road section more smoothly compared to lower value. 2007-07 Thesis http://eprints.utm.my/id/eprint/6412/ http://eprints.utm.my/id/eprint/6412/1/NordianaMashrosMFKA2007.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering |
institution |
Universiti Teknologi Malaysia |
collection |
UTM Institutional Repository |
language |
English |
topic |
HE Transportation and Communications HE Transportation and Communications |
spellingShingle |
HE Transportation and Communications HE Transportation and Communications Mashros, Nordiana Platoon dispersion downstream of traffic signal |
description |
The potential benefits of studying platoon dispersion downstream of traffic signal are already known in traffic flow analysis, modelling and traffic engineering design. However, presently there is a lack of information on platoon dispersion on Malaysian roads. This study determines the arrival distribution pattern downstream of traffic signal which includes vehicle headway, intra-platoon headway and inter-platoon headway. It also looked into the roadway characteristic that affects platoon dispersion. Data for more than 1000 vehicles were collected using video cameras to record traffic movement at Saleng, Kulai. Vehicle type and time were determined for each vehicle on a per lane basis during the morning peak and off peak hours at several consecutive points downstream of traffic signal for analysis. Four mathematical distribution models namely shifted negative exponential distribution, erlang distribution, schuhl distribution and double displaced negative exponential distribution were fitted to the actual distribution data. It was observed that vehicle headways follow the shifted negative exponential distribution with shift equals to 1.0s, the intra-platoon headways have normal distribution and inter-platoon headways do not fit to any of the tested distribution models under peak and off peak hours. The level of friction at this road section is of low friction. The values of platoon dispersion factor and travel time factor are 0.16 and 0.86 during peak hour and 0.22 and 0.82 during off peak hour. The values of smoothing factor under these conditions are 0.21 (peak hour) and 0.17 (off peak hour). The higher value of smoothing factor indicates that the vehicles are able to travel on the road section more smoothly compared to lower value. |
format |
Thesis |
qualification_level |
Master's degree |
author |
Mashros, Nordiana |
author_facet |
Mashros, Nordiana |
author_sort |
Mashros, Nordiana |
title |
Platoon dispersion downstream of traffic signal |
title_short |
Platoon dispersion downstream of traffic signal |
title_full |
Platoon dispersion downstream of traffic signal |
title_fullStr |
Platoon dispersion downstream of traffic signal |
title_full_unstemmed |
Platoon dispersion downstream of traffic signal |
title_sort |
platoon dispersion downstream of traffic signal |
granting_institution |
Universiti Teknologi Malaysia, Faculty of Civil Engineering |
granting_department |
Faculty of Civil Engineering |
publishDate |
2007 |
url |
http://eprints.utm.my/id/eprint/6412/1/NordianaMashrosMFKA2007.pdf |
_version_ |
1747814653975592960 |