Rekabentuk pengelog data harmonik dan suhu berbilang saluran untuk pemantauan pengubah

Increasing use of non-linear loads in recent years has increased significantly the presence of harmonics in the power system. The presence of harmonics in the power distribution will cause excessive winding loss in power system components and abnormal temperature rise, which will shorten the life sp...

Full description

Saved in:
Bibliographic Details
Main Author: Syamsir, Hendri Novia
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/77665/1/HendriNoviaSyamsirPFKE2015.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.77665
record_format uketd_dc
spelling my-utm-ep.776652018-06-26T07:50:00Z Rekabentuk pengelog data harmonik dan suhu berbilang saluran untuk pemantauan pengubah 2015-08 Syamsir, Hendri Novia TK Electrical engineering. Electronics Nuclear engineering Increasing use of non-linear loads in recent years has increased significantly the presence of harmonics in the power system. The presence of harmonics in the power distribution will cause excessive winding loss in power system components and abnormal temperature rise, which will shorten the life span of the transformer and lead to the increase in operational costs. The harmonic presence in the power distribution system can be identified by harmonic measurements. This situation must be taken into account before the failure of the transformer. If the transformer fails to operate with the expected lifetime, it will cause a huge loss. This thesis presents a preliminary method of transformer maintenance, due to the effect of non-linear load on the transformer temperature rise, using a designed of multi-channel\ data logger. In this study, a method has been proposed to monitor and identify the transformer condition. This method has been done by recording the power quality data of a transformer. Data is taken at all channels of distribution and transformer temperature simultaneously. Measurement is performed for operating transformer by using the multi-channel data logger. This method is more efficient than a normal data logger, which has only one channel. The data logger is designed using quality power transducers CT1700. Microcomputer modules VSX-6154 is used as the processor. The program is developed using Borland C ++ and Visual Basic 6.0 with RS232 serial communication. The equipment cost is at lower price than other commercial data logger. The accuracy was confirmed by the National Metrology Laboratory SIRIM. The advantages of this tool are to simultaneously capture data harmonics up to number 21 and temperature simultaneously for 10 channels. The data obtained helps an early response before the transformer fails completely, and this may save high operational costs. 2015-08 Thesis http://eprints.utm.my/id/eprint/77665/ http://eprints.utm.my/id/eprint/77665/1/HendriNoviaSyamsirPFKE2015.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:95166 phd doctoral Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Syamsir, Hendri Novia
Rekabentuk pengelog data harmonik dan suhu berbilang saluran untuk pemantauan pengubah
description Increasing use of non-linear loads in recent years has increased significantly the presence of harmonics in the power system. The presence of harmonics in the power distribution will cause excessive winding loss in power system components and abnormal temperature rise, which will shorten the life span of the transformer and lead to the increase in operational costs. The harmonic presence in the power distribution system can be identified by harmonic measurements. This situation must be taken into account before the failure of the transformer. If the transformer fails to operate with the expected lifetime, it will cause a huge loss. This thesis presents a preliminary method of transformer maintenance, due to the effect of non-linear load on the transformer temperature rise, using a designed of multi-channel\ data logger. In this study, a method has been proposed to monitor and identify the transformer condition. This method has been done by recording the power quality data of a transformer. Data is taken at all channels of distribution and transformer temperature simultaneously. Measurement is performed for operating transformer by using the multi-channel data logger. This method is more efficient than a normal data logger, which has only one channel. The data logger is designed using quality power transducers CT1700. Microcomputer modules VSX-6154 is used as the processor. The program is developed using Borland C ++ and Visual Basic 6.0 with RS232 serial communication. The equipment cost is at lower price than other commercial data logger. The accuracy was confirmed by the National Metrology Laboratory SIRIM. The advantages of this tool are to simultaneously capture data harmonics up to number 21 and temperature simultaneously for 10 channels. The data obtained helps an early response before the transformer fails completely, and this may save high operational costs.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Syamsir, Hendri Novia
author_facet Syamsir, Hendri Novia
author_sort Syamsir, Hendri Novia
title Rekabentuk pengelog data harmonik dan suhu berbilang saluran untuk pemantauan pengubah
title_short Rekabentuk pengelog data harmonik dan suhu berbilang saluran untuk pemantauan pengubah
title_full Rekabentuk pengelog data harmonik dan suhu berbilang saluran untuk pemantauan pengubah
title_fullStr Rekabentuk pengelog data harmonik dan suhu berbilang saluran untuk pemantauan pengubah
title_full_unstemmed Rekabentuk pengelog data harmonik dan suhu berbilang saluran untuk pemantauan pengubah
title_sort rekabentuk pengelog data harmonik dan suhu berbilang saluran untuk pemantauan pengubah
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2015
url http://eprints.utm.my/id/eprint/77665/1/HendriNoviaSyamsirPFKE2015.pdf
_version_ 1747817802791649280