Reducing indoor air contaminants inside a campus bus passenger compartment

Good ventilation system is important to provide fresh air and comfortable environment for passengers. Lack of fresh air inside a bus compartment may cause various illnesses such as headache, asthma, cardiovascular and lung cancer. Two factors influence the ventilation system effectiveness namely the...

Full description

Saved in:
Bibliographic Details
Main Author: Ahmad Shafie, Noor Emilia
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/77791/1/NoorEmiliaAhmadPFKM2016.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.77791
record_format uketd_dc
spelling my-utm-ep.777912018-07-04T11:44:27Z Reducing indoor air contaminants inside a campus bus passenger compartment 2016-03 Ahmad Shafie, Noor Emilia TJ Mechanical engineering and machinery Good ventilation system is important to provide fresh air and comfortable environment for passengers. Lack of fresh air inside a bus compartment may cause various illnesses such as headache, asthma, cardiovascular and lung cancer. Two factors influence the ventilation system effectiveness namely the arrangement of air supply diffusers and the air return grilles. This thesis presents a study on air contaminants inside a university’s bus passenger compartment. The goal is to find a suitable ventilation arrangement that can reduce the concentration of the air contaminants. First a field measurement was carried out on a selected bus to measure the air contaminants at the front section, middle section and rear section. The contaminants include carbon monoxide, carbon dioxide, formaldehyde and particulate matter. Then computational fluid dynamics flow analyses were carried out on simplified model of the bus compartment employing renormalization group k-ε model for air flow, species transport for gases and discrete phase for particles. Five cases of ventilation arrangements were considered namely displacement ventilation with two air return grilles, underfloor air distribution with two air return grilles, mixing ventilation with four air return grilles, displacement ventilation with four air return grilles and underfloor air distribution with four air return grilles. It was found from the field measurements that the concentration of carbon monoxide, carbon dioxide, formaldehyde, particulate matter 1, particulate matter 2.5 and particulate matter 10 were 7 ppm, 1102 ppm, 0.18 ppm, 52 μg/m3, 52 μg/m3 and 51 μg/m3, respectively. Results of flow simulations show that the underfloor air distribution with four air return grilles is able to reduce the contaminants concentration inside the passenger compartment. On average, the concentrations of carbon monoxide, carbon dioxide, formaldehyde, particulate matter 1, particulate matter 2.5 and particulate matter 10 were reduced by about 40%, 10%, 38%, 37%, 33% and 30%, respectively. 2016-03 Thesis http://eprints.utm.my/id/eprint/77791/ http://eprints.utm.my/id/eprint/77791/1/NoorEmiliaAhmadPFKM2016.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:98191 phd doctoral Universiti Teknologi Malaysia, Faculty of Mechanical Engineering Faculty of Mechanical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Ahmad Shafie, Noor Emilia
Reducing indoor air contaminants inside a campus bus passenger compartment
description Good ventilation system is important to provide fresh air and comfortable environment for passengers. Lack of fresh air inside a bus compartment may cause various illnesses such as headache, asthma, cardiovascular and lung cancer. Two factors influence the ventilation system effectiveness namely the arrangement of air supply diffusers and the air return grilles. This thesis presents a study on air contaminants inside a university’s bus passenger compartment. The goal is to find a suitable ventilation arrangement that can reduce the concentration of the air contaminants. First a field measurement was carried out on a selected bus to measure the air contaminants at the front section, middle section and rear section. The contaminants include carbon monoxide, carbon dioxide, formaldehyde and particulate matter. Then computational fluid dynamics flow analyses were carried out on simplified model of the bus compartment employing renormalization group k-ε model for air flow, species transport for gases and discrete phase for particles. Five cases of ventilation arrangements were considered namely displacement ventilation with two air return grilles, underfloor air distribution with two air return grilles, mixing ventilation with four air return grilles, displacement ventilation with four air return grilles and underfloor air distribution with four air return grilles. It was found from the field measurements that the concentration of carbon monoxide, carbon dioxide, formaldehyde, particulate matter 1, particulate matter 2.5 and particulate matter 10 were 7 ppm, 1102 ppm, 0.18 ppm, 52 μg/m3, 52 μg/m3 and 51 μg/m3, respectively. Results of flow simulations show that the underfloor air distribution with four air return grilles is able to reduce the contaminants concentration inside the passenger compartment. On average, the concentrations of carbon monoxide, carbon dioxide, formaldehyde, particulate matter 1, particulate matter 2.5 and particulate matter 10 were reduced by about 40%, 10%, 38%, 37%, 33% and 30%, respectively.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Ahmad Shafie, Noor Emilia
author_facet Ahmad Shafie, Noor Emilia
author_sort Ahmad Shafie, Noor Emilia
title Reducing indoor air contaminants inside a campus bus passenger compartment
title_short Reducing indoor air contaminants inside a campus bus passenger compartment
title_full Reducing indoor air contaminants inside a campus bus passenger compartment
title_fullStr Reducing indoor air contaminants inside a campus bus passenger compartment
title_full_unstemmed Reducing indoor air contaminants inside a campus bus passenger compartment
title_sort reducing indoor air contaminants inside a campus bus passenger compartment
granting_institution Universiti Teknologi Malaysia, Faculty of Mechanical Engineering
granting_department Faculty of Mechanical Engineering
publishDate 2016
url http://eprints.utm.my/id/eprint/77791/1/NoorEmiliaAhmadPFKM2016.pdf
_version_ 1747817831870758912