Mitigation of load harmonics from grid connected wind turbine using shunt active power filter

The increasing utilization of power electronics controlled devices in power system has increased distortion level in current and voltage waveforms in the form of harmonics. The increase in harmonic level also affects the performance of generator, thereby reducing its efficiency and lifespan. In this...

Full description

Saved in:
Bibliographic Details
Main Author: Qazi, Sajid Hussain
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/77900/1/SajidHussainQaziMFKE2016.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.77900
record_format uketd_dc
spelling my-utm-ep.779002018-07-18T04:11:17Z Mitigation of load harmonics from grid connected wind turbine using shunt active power filter 2016-02 Qazi, Sajid Hussain TK Electrical engineering. Electronics Nuclear engineering The increasing utilization of power electronics controlled devices in power system has increased distortion level in current and voltage waveforms in the form of harmonics. The increase in harmonic level also affects the performance of generator, thereby reducing its efficiency and lifespan. In this research, load harmonic mitigation method has been proposed for grid connected variable speed wind turbine generator using Shunt Active Power Filter (APF). The main advantage of this method is eliminating the effect of load harmonics from terminals of wind turbine generator and from the Point of Common Coupling (PCC). To evaluate the performance of shunt APF, two strategies have been utilized separately for extracting harmonic reference signal: the instantaneous reactive power method (pq method) and Synchronous Reference Frame (SRF) technique. To prove the effectiveness of the proposed system, MATLAB simulations have been carried out on 120 kV grid connected Permanent Magnet Synchronous Generator (PMSG) based wind turbine. Furthermore, nonlinear load is also attached to PCC under fixed and variable wind speed between 8 to 12 m/s separately. For proper operation of APF, switching pulses have been produced by hysteresis band current control. This technique decreases the magnitude of Total Harmonic Distortion (THD) to an acceptable limit set by IEEE-519 standard for harmonic control. Results have also shown that the shunt APF with SRF technique yields better performance under fixed and fluctuating wind speed compared to pq method. 2016-02 Thesis http://eprints.utm.my/id/eprint/77900/ http://eprints.utm.my/id/eprint/77900/1/SajidHussainQaziMFKE2016.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:94094 masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Qazi, Sajid Hussain
Mitigation of load harmonics from grid connected wind turbine using shunt active power filter
description The increasing utilization of power electronics controlled devices in power system has increased distortion level in current and voltage waveforms in the form of harmonics. The increase in harmonic level also affects the performance of generator, thereby reducing its efficiency and lifespan. In this research, load harmonic mitigation method has been proposed for grid connected variable speed wind turbine generator using Shunt Active Power Filter (APF). The main advantage of this method is eliminating the effect of load harmonics from terminals of wind turbine generator and from the Point of Common Coupling (PCC). To evaluate the performance of shunt APF, two strategies have been utilized separately for extracting harmonic reference signal: the instantaneous reactive power method (pq method) and Synchronous Reference Frame (SRF) technique. To prove the effectiveness of the proposed system, MATLAB simulations have been carried out on 120 kV grid connected Permanent Magnet Synchronous Generator (PMSG) based wind turbine. Furthermore, nonlinear load is also attached to PCC under fixed and variable wind speed between 8 to 12 m/s separately. For proper operation of APF, switching pulses have been produced by hysteresis band current control. This technique decreases the magnitude of Total Harmonic Distortion (THD) to an acceptable limit set by IEEE-519 standard for harmonic control. Results have also shown that the shunt APF with SRF technique yields better performance under fixed and fluctuating wind speed compared to pq method.
format Thesis
qualification_level Master's degree
author Qazi, Sajid Hussain
author_facet Qazi, Sajid Hussain
author_sort Qazi, Sajid Hussain
title Mitigation of load harmonics from grid connected wind turbine using shunt active power filter
title_short Mitigation of load harmonics from grid connected wind turbine using shunt active power filter
title_full Mitigation of load harmonics from grid connected wind turbine using shunt active power filter
title_fullStr Mitigation of load harmonics from grid connected wind turbine using shunt active power filter
title_full_unstemmed Mitigation of load harmonics from grid connected wind turbine using shunt active power filter
title_sort mitigation of load harmonics from grid connected wind turbine using shunt active power filter
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2016
url http://eprints.utm.my/id/eprint/77900/1/SajidHussainQaziMFKE2016.pdf
_version_ 1747817858575892480