Plasma parameters characterization of laser induced breakdown spectroscopy on solid materials at different wavelengths

The purpose of this research is to investigate the influence of laser wavelength on the plasma parameters in Laser Induced Breakdown of three different types of samples. The samples used were carbon rod, iron rod and stainless steel which represent non-metal, metal and alloy sample respectively. The...

全面介紹

Saved in:
書目詳細資料
主要作者: Tan Halid, Nurul Shuhada
格式: Thesis
語言:English
出版: 2017
主題:
在線閱讀:http://eprints.utm.my/id/eprint/78384/1/NurulShuhadaTanMFS2017.pdf
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my-utm-ep.78384
record_format uketd_dc
spelling my-utm-ep.783842018-08-26T04:56:18Z Plasma parameters characterization of laser induced breakdown spectroscopy on solid materials at different wavelengths 2017-05 Tan Halid, Nurul Shuhada QC Physics The purpose of this research is to investigate the influence of laser wavelength on the plasma parameters in Laser Induced Breakdown of three different types of samples. The samples used were carbon rod, iron rod and stainless steel which represent non-metal, metal and alloy sample respectively. The source used is Nd:YAG laser operating at 1064 nm and 532 nm with laser energy of 150 mJ and 110 mJ respectively. The experiment was conducted in air at atmospheric pressure. The samples were placed at 5 cm, approximately 45º from a detector and 12 cm from the laser source. The plasma emission spectra were recorded and analyzed. Plasma parameters that have been taken into consideration were plasma emission spectrum, area of ablated surface, plasma spark shape, plasma electron temperature and plasma electron density. The results show that each sample produced different emission spectra. In addition the carbon sample shows the largest circular ablated area with radius 1.313 mm when generated using 1064 nm laser. Each sample produces different shapes of plasma sparks when generated using both laser sources. The plasma electron temperatures of carbon and iron samples produced by 1064 nm laser were estimated at 36671 K and 28200 K respectively while those generated with 532 nm laser were at 27271 K and 21585 K respectively. The stainless steel is consisted of Fe, Ni, Cr and Mn elements. The plasma electron temperatures of these elements were 21005 K, 2901 K, 10676 K and 12649 K respectively when generated using 1064 nm laser and 15202 K, 2785 K, 9748 K and 11697 K respectively using 532 nm laser. The other result shows that carbon rod as a non-metal sample has the highest plasma electron density when generated using 532 nm laser while the stainless steel sample has the highest plasma electron density when used with 1064 nm laser. In conclusions, the plasma emission spectra in all samples have been captured. The study shows that both types of laser are suitable for elemental detection. The plasma electron temperature and the plasma electron density have been determined for both laser sources. 2017-05 Thesis http://eprints.utm.my/id/eprint/78384/ http://eprints.utm.my/id/eprint/78384/1/NurulShuhadaTanMFS2017.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:105057 masters Universiti Teknologi Malaysia, Faculty of Science Faculty of Science
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic QC Physics
spellingShingle QC Physics
Tan Halid, Nurul Shuhada
Plasma parameters characterization of laser induced breakdown spectroscopy on solid materials at different wavelengths
description The purpose of this research is to investigate the influence of laser wavelength on the plasma parameters in Laser Induced Breakdown of three different types of samples. The samples used were carbon rod, iron rod and stainless steel which represent non-metal, metal and alloy sample respectively. The source used is Nd:YAG laser operating at 1064 nm and 532 nm with laser energy of 150 mJ and 110 mJ respectively. The experiment was conducted in air at atmospheric pressure. The samples were placed at 5 cm, approximately 45º from a detector and 12 cm from the laser source. The plasma emission spectra were recorded and analyzed. Plasma parameters that have been taken into consideration were plasma emission spectrum, area of ablated surface, plasma spark shape, plasma electron temperature and plasma electron density. The results show that each sample produced different emission spectra. In addition the carbon sample shows the largest circular ablated area with radius 1.313 mm when generated using 1064 nm laser. Each sample produces different shapes of plasma sparks when generated using both laser sources. The plasma electron temperatures of carbon and iron samples produced by 1064 nm laser were estimated at 36671 K and 28200 K respectively while those generated with 532 nm laser were at 27271 K and 21585 K respectively. The stainless steel is consisted of Fe, Ni, Cr and Mn elements. The plasma electron temperatures of these elements were 21005 K, 2901 K, 10676 K and 12649 K respectively when generated using 1064 nm laser and 15202 K, 2785 K, 9748 K and 11697 K respectively using 532 nm laser. The other result shows that carbon rod as a non-metal sample has the highest plasma electron density when generated using 532 nm laser while the stainless steel sample has the highest plasma electron density when used with 1064 nm laser. In conclusions, the plasma emission spectra in all samples have been captured. The study shows that both types of laser are suitable for elemental detection. The plasma electron temperature and the plasma electron density have been determined for both laser sources.
format Thesis
qualification_level Master's degree
author Tan Halid, Nurul Shuhada
author_facet Tan Halid, Nurul Shuhada
author_sort Tan Halid, Nurul Shuhada
title Plasma parameters characterization of laser induced breakdown spectroscopy on solid materials at different wavelengths
title_short Plasma parameters characterization of laser induced breakdown spectroscopy on solid materials at different wavelengths
title_full Plasma parameters characterization of laser induced breakdown spectroscopy on solid materials at different wavelengths
title_fullStr Plasma parameters characterization of laser induced breakdown spectroscopy on solid materials at different wavelengths
title_full_unstemmed Plasma parameters characterization of laser induced breakdown spectroscopy on solid materials at different wavelengths
title_sort plasma parameters characterization of laser induced breakdown spectroscopy on solid materials at different wavelengths
granting_institution Universiti Teknologi Malaysia, Faculty of Science
granting_department Faculty of Science
publishDate 2017
url http://eprints.utm.my/id/eprint/78384/1/NurulShuhadaTanMFS2017.pdf
_version_ 1747817976073027584