Three dimensional surface reconstruction of lower limb prosthetic model using infrared sensor array

This thesis addresses the development of a shape detector device using infrared sensor to reconstruct a three-dimensional image of an object. The threedimension image is produced based on the object surface using image processing technique. Conventionally, infrared sensors are used for detection of...

Full description

Saved in:
Bibliographic Details
Main Author: Daud, Siti Asmah
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/78532/1/SitiAsmahDaudPFBME2016.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.78532
record_format uketd_dc
spelling my-utm-ep.785322018-08-27T03:24:16Z Three dimensional surface reconstruction of lower limb prosthetic model using infrared sensor array 2016-01 Daud, Siti Asmah QH Natural history This thesis addresses the development of a shape detector device using infrared sensor to reconstruct a three-dimensional image of an object. The threedimension image is produced based on the object surface using image processing technique. Conventionally, infrared sensors are used for detection of an obstacle and distance measurement to avoid collisions. However, it is not common to use infrared sensors to measure the size of an object. Hence, this research aims to investigate the feasibility of infrared sensors in measuring the object dimension for three-dimension image reconstruction. Experiments were executed to study the minimum distance range utilising GP2D120 infrared sensor. From the experiment, the distance between the sensor and object surface should be more than 5 cm. The scanning device consists of the infrared sensor array was placed in a black box with the object in the center. The scanning process required the object to turn 360 ° clockwise in an xy plane and the resolution for z-axis is 2 mm, in order to obtain data for the image reconstruction. Reference polygon shape models with various dimensions were used as scanning objects in the experiments. The device scans object diameter every 2 mm in thickness, 100 mm in height, and the total time required to collect data for each layer is 60 seconds. The reconstructed object accuracy is above 80 % based on the comparison between a solid and printed model dimension. Four different lower limb prosthetic models with different shapes were used as the object in the scanning experiments. The experimental findings show that the prosthetic shapes reconstructed with an average accuracy of 97 %. This system shows good reproducibility where the collected data using the infrared sensor device need further improvement so that it can be applied in medical field for orthotics and prosthetics purpose. 2016-01 Thesis http://eprints.utm.my/id/eprint/78532/ http://eprints.utm.my/id/eprint/78532/1/SitiAsmahDaudPFBME2016.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:97149 phd doctoral Universiti Teknologi Malaysia, Faculty of Biosciences and Medical Engineering Faculty of Biosciences and Medical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic QH Natural history
spellingShingle QH Natural history
Daud, Siti Asmah
Three dimensional surface reconstruction of lower limb prosthetic model using infrared sensor array
description This thesis addresses the development of a shape detector device using infrared sensor to reconstruct a three-dimensional image of an object. The threedimension image is produced based on the object surface using image processing technique. Conventionally, infrared sensors are used for detection of an obstacle and distance measurement to avoid collisions. However, it is not common to use infrared sensors to measure the size of an object. Hence, this research aims to investigate the feasibility of infrared sensors in measuring the object dimension for three-dimension image reconstruction. Experiments were executed to study the minimum distance range utilising GP2D120 infrared sensor. From the experiment, the distance between the sensor and object surface should be more than 5 cm. The scanning device consists of the infrared sensor array was placed in a black box with the object in the center. The scanning process required the object to turn 360 ° clockwise in an xy plane and the resolution for z-axis is 2 mm, in order to obtain data for the image reconstruction. Reference polygon shape models with various dimensions were used as scanning objects in the experiments. The device scans object diameter every 2 mm in thickness, 100 mm in height, and the total time required to collect data for each layer is 60 seconds. The reconstructed object accuracy is above 80 % based on the comparison between a solid and printed model dimension. Four different lower limb prosthetic models with different shapes were used as the object in the scanning experiments. The experimental findings show that the prosthetic shapes reconstructed with an average accuracy of 97 %. This system shows good reproducibility where the collected data using the infrared sensor device need further improvement so that it can be applied in medical field for orthotics and prosthetics purpose.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Daud, Siti Asmah
author_facet Daud, Siti Asmah
author_sort Daud, Siti Asmah
title Three dimensional surface reconstruction of lower limb prosthetic model using infrared sensor array
title_short Three dimensional surface reconstruction of lower limb prosthetic model using infrared sensor array
title_full Three dimensional surface reconstruction of lower limb prosthetic model using infrared sensor array
title_fullStr Three dimensional surface reconstruction of lower limb prosthetic model using infrared sensor array
title_full_unstemmed Three dimensional surface reconstruction of lower limb prosthetic model using infrared sensor array
title_sort three dimensional surface reconstruction of lower limb prosthetic model using infrared sensor array
granting_institution Universiti Teknologi Malaysia, Faculty of Biosciences and Medical Engineering
granting_department Faculty of Biosciences and Medical Engineering
publishDate 2016
url http://eprints.utm.my/id/eprint/78532/1/SitiAsmahDaudPFBME2016.pdf
_version_ 1747818008286330880