Urinary human papillomavirus DNA detection using piezoelectric biosensor

Cervical cancer is a disease that remains a concern for women worldwide. Despite the implementation of standard Pap test and the HPV test, the screening coverage is still low due to its invasive nature as both involve the collection of cervical samples. The HPV screening test itself is expensive, ex...

Full description

Saved in:
Bibliographic Details
Main Author: Abd. Karim, Nur Amani
Format: Thesis
Language:English
Published: 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/78930/1/NurAmaniAbdMFBME2017.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.78930
record_format uketd_dc
spelling my-utm-ep.789302018-09-17T07:23:19Z Urinary human papillomavirus DNA detection using piezoelectric biosensor 2017-03 Abd. Karim, Nur Amani QH301 Biology Cervical cancer is a disease that remains a concern for women worldwide. Despite the implementation of standard Pap test and the HPV test, the screening coverage is still low due to its invasive nature as both involve the collection of cervical samples. The HPV screening test itself is expensive, extensive and label-dependent. In this pilot study, piezoelectric biosensor was used for HPV DNA detection in urine due to its non-invasive approach, simplicity, low instrumentation costs, and label-free detection. Urine samples were collected from 21 women with abnormal Pap Test results and 19 women with normal Pap Test results. HPV HR piezoelectric biosensor was developed for the detection of 3 high-risk HPV DNA strains (16, 18, and 33) and HPV 16 piezoelectric biosensor is for the detection of only HPV 16 DNA. Probe optimisation and calibration experiments were carried out. Amplified urinary DNA samples were analysed using the biosensors. Results showed that the optimum probe concentration for both biosensors was 1.0 μM. The biosensor was able to detect the presence of complementary target DNAs with high specificity. For HPV HR piezoelectric biosensor, the sensitivity was 97.99 Hz μM -1, the instrument detection limit was 16.36 Hz and the concentration detection limit was 0.10344 μM. Meanwhile, for HPV 16 DNA piezoelectric biosensor, the sensitivity was 99.19 Hz μM -1, the instrument detection limit was 15.14 Hz and the concentration detection limit was 0.088 μM. The clinical sensitivity and specificity for both types of piezoelectric biosensor were both 100%. These preliminary results allow for the possibility of implementing the piezoelectric biosensor for the detection of urinary HPV DNA as a potential alternative screening method. 2017-03 Thesis http://eprints.utm.my/id/eprint/78930/ http://eprints.utm.my/id/eprint/78930/1/NurAmaniAbdMFBME2017.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:110568 masters Universiti Teknologi Malaysia, Faculty of Biosciences and Medical Engineering Faculty of Biosciences and Medical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic QH301 Biology
spellingShingle QH301 Biology
Abd. Karim, Nur Amani
Urinary human papillomavirus DNA detection using piezoelectric biosensor
description Cervical cancer is a disease that remains a concern for women worldwide. Despite the implementation of standard Pap test and the HPV test, the screening coverage is still low due to its invasive nature as both involve the collection of cervical samples. The HPV screening test itself is expensive, extensive and label-dependent. In this pilot study, piezoelectric biosensor was used for HPV DNA detection in urine due to its non-invasive approach, simplicity, low instrumentation costs, and label-free detection. Urine samples were collected from 21 women with abnormal Pap Test results and 19 women with normal Pap Test results. HPV HR piezoelectric biosensor was developed for the detection of 3 high-risk HPV DNA strains (16, 18, and 33) and HPV 16 piezoelectric biosensor is for the detection of only HPV 16 DNA. Probe optimisation and calibration experiments were carried out. Amplified urinary DNA samples were analysed using the biosensors. Results showed that the optimum probe concentration for both biosensors was 1.0 μM. The biosensor was able to detect the presence of complementary target DNAs with high specificity. For HPV HR piezoelectric biosensor, the sensitivity was 97.99 Hz μM -1, the instrument detection limit was 16.36 Hz and the concentration detection limit was 0.10344 μM. Meanwhile, for HPV 16 DNA piezoelectric biosensor, the sensitivity was 99.19 Hz μM -1, the instrument detection limit was 15.14 Hz and the concentration detection limit was 0.088 μM. The clinical sensitivity and specificity for both types of piezoelectric biosensor were both 100%. These preliminary results allow for the possibility of implementing the piezoelectric biosensor for the detection of urinary HPV DNA as a potential alternative screening method.
format Thesis
qualification_level Master's degree
author Abd. Karim, Nur Amani
author_facet Abd. Karim, Nur Amani
author_sort Abd. Karim, Nur Amani
title Urinary human papillomavirus DNA detection using piezoelectric biosensor
title_short Urinary human papillomavirus DNA detection using piezoelectric biosensor
title_full Urinary human papillomavirus DNA detection using piezoelectric biosensor
title_fullStr Urinary human papillomavirus DNA detection using piezoelectric biosensor
title_full_unstemmed Urinary human papillomavirus DNA detection using piezoelectric biosensor
title_sort urinary human papillomavirus dna detection using piezoelectric biosensor
granting_institution Universiti Teknologi Malaysia, Faculty of Biosciences and Medical Engineering
granting_department Faculty of Biosciences and Medical Engineering
publishDate 2017
url http://eprints.utm.my/id/eprint/78930/1/NurAmaniAbdMFBME2017.pdf
_version_ 1747818106355449856