Comparative analysis between net and gross metering based feed-in tariff

Depleting gas and oil have encouraged scientist and governments to seek other alternatives. Renewable Energy (RE) resources have been the best option as a solution for the time being issue. In order to achieve rapid development of RE resources usage, Feed in-Tariff has been introduced and applied. F...

Full description

Saved in:
Bibliographic Details
Main Author: Alasadi, Samarah Qasim Ali
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/79027/1/SamarahQasimAliMFKE2017.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.79027
record_format uketd_dc
spelling my-utm-ep.790272018-09-27T04:14:36Z Comparative analysis between net and gross metering based feed-in tariff 2016-12 Alasadi, Samarah Qasim Ali TK Electrical engineering. Electronics Nuclear engineering Depleting gas and oil have encouraged scientist and governments to seek other alternatives. Renewable Energy (RE) resources have been the best option as a solution for the time being issue. In order to achieve rapid development of RE resources usage, Feed in-Tariff has been introduced and applied. FIT considers as an energy supply policy that offers a guarantee of payment to RE developers for the electricity the customers produce. It incentive to encourage uptake of RE technology including photovoltaic (PV) and wind turbines and other technologies. There are two different types of metering systems, Gross and Net metering. Gross metering policy is to pay customers for both RE installation and for the generated electricity weather it has been consumed or injected directly to the grid. However, Net metering policy only considers the difference of the injected and the consumed electricity. The customers are paid only if their electricity consumption is less than their generation. This project compares the results for Net and Gross metering system for various load cases. The works presented here include i) review different FIT scheme metering system for various countries, ii) to make different case studies for different loads scenarios for UTM load and a typical Malaysian house, in JB, comparing it to a European (Portugal) house and the analyses is performed by using Homer software. All cases will be considering grid connecting PV system. The effect of financial factor like payback period, NPC (Vet Present Cost) and COE (Cost of Electricity) are used in the comparison. Results showed that Gross metering was preferable for Malaysian domestic or commercial load because it has less COE, NPC and less payback period comparing to Net metering system. 2016-12 Thesis http://eprints.utm.my/id/eprint/79027/ http://eprints.utm.my/id/eprint/79027/1/SamarahQasimAliMFKE2017.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:109731 masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Alasadi, Samarah Qasim Ali
Comparative analysis between net and gross metering based feed-in tariff
description Depleting gas and oil have encouraged scientist and governments to seek other alternatives. Renewable Energy (RE) resources have been the best option as a solution for the time being issue. In order to achieve rapid development of RE resources usage, Feed in-Tariff has been introduced and applied. FIT considers as an energy supply policy that offers a guarantee of payment to RE developers for the electricity the customers produce. It incentive to encourage uptake of RE technology including photovoltaic (PV) and wind turbines and other technologies. There are two different types of metering systems, Gross and Net metering. Gross metering policy is to pay customers for both RE installation and for the generated electricity weather it has been consumed or injected directly to the grid. However, Net metering policy only considers the difference of the injected and the consumed electricity. The customers are paid only if their electricity consumption is less than their generation. This project compares the results for Net and Gross metering system for various load cases. The works presented here include i) review different FIT scheme metering system for various countries, ii) to make different case studies for different loads scenarios for UTM load and a typical Malaysian house, in JB, comparing it to a European (Portugal) house and the analyses is performed by using Homer software. All cases will be considering grid connecting PV system. The effect of financial factor like payback period, NPC (Vet Present Cost) and COE (Cost of Electricity) are used in the comparison. Results showed that Gross metering was preferable for Malaysian domestic or commercial load because it has less COE, NPC and less payback period comparing to Net metering system.
format Thesis
qualification_level Master's degree
author Alasadi, Samarah Qasim Ali
author_facet Alasadi, Samarah Qasim Ali
author_sort Alasadi, Samarah Qasim Ali
title Comparative analysis between net and gross metering based feed-in tariff
title_short Comparative analysis between net and gross metering based feed-in tariff
title_full Comparative analysis between net and gross metering based feed-in tariff
title_fullStr Comparative analysis between net and gross metering based feed-in tariff
title_full_unstemmed Comparative analysis between net and gross metering based feed-in tariff
title_sort comparative analysis between net and gross metering based feed-in tariff
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2016
url http://eprints.utm.my/id/eprint/79027/1/SamarahQasimAliMFKE2017.pdf
_version_ 1747818129170366464