Design behaviour of cold-formed steel encased composite beam with protruded link

Composite action of a structural member can be obtained with the combination of concrete and steel. This composite action is achieved through the use of a shear connector. The shear connector resists the horizontal shear by producing vertical interlocking between the concrete slab and steel beam, as...

Full description

Saved in:
Bibliographic Details
Main Author: Buhari, Suffian
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/79049/1/SuffianBuhariMFKA2018.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.79049
record_format uketd_dc
spelling my-utm-ep.790492018-09-27T04:15:47Z Design behaviour of cold-formed steel encased composite beam with protruded link 2018-01 Buhari, Suffian TA Engineering (General). Civil engineering (General) Composite action of a structural member can be obtained with the combination of concrete and steel. This composite action is achieved through the use of a shear connector. The shear connector resists the horizontal shear by producing vertical interlocking between the concrete slab and steel beam, as a single composite unit. Typical composite beam is consist of I-beam in combination with concrete slab by the aid of a shear connector called stud. However, this study intends to investigate the design behaviour of a link protruded into the concrete slab to act as the shear connector. The moment and shear capacities of the composite cold-formed encased steel beam with protruded link are obtained and compared with the conventional reinforced concrete beam and composite steel beam. A calculation with several different parameters were compared to determine the influence of the parameter that affected the resistance of the moment and shear capacities of the beam. Design calculation for the reinforced concrete beam is carried out using EN1992 (EC2) while the design calculation for the composite steel beam and composite cold-formed encased steel beam with protruded link are carried out using EN1993 (EC3) and EN1994 (EC4) respectively. It has been found that composite cold-formed encased steel beam with protruded link can increase the value of moment and shear capacities compared to the reinforced concrete beam and composite steel beam. In conclusion, this study shows that the effect of the protruded link can enhance the moment and shear capacities of the composite coldformed encased steel beam. 2018-01 Thesis http://eprints.utm.my/id/eprint/79049/ http://eprints.utm.my/id/eprint/79049/1/SuffianBuhariMFKA2018.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:108561 masters Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Buhari, Suffian
Design behaviour of cold-formed steel encased composite beam with protruded link
description Composite action of a structural member can be obtained with the combination of concrete and steel. This composite action is achieved through the use of a shear connector. The shear connector resists the horizontal shear by producing vertical interlocking between the concrete slab and steel beam, as a single composite unit. Typical composite beam is consist of I-beam in combination with concrete slab by the aid of a shear connector called stud. However, this study intends to investigate the design behaviour of a link protruded into the concrete slab to act as the shear connector. The moment and shear capacities of the composite cold-formed encased steel beam with protruded link are obtained and compared with the conventional reinforced concrete beam and composite steel beam. A calculation with several different parameters were compared to determine the influence of the parameter that affected the resistance of the moment and shear capacities of the beam. Design calculation for the reinforced concrete beam is carried out using EN1992 (EC2) while the design calculation for the composite steel beam and composite cold-formed encased steel beam with protruded link are carried out using EN1993 (EC3) and EN1994 (EC4) respectively. It has been found that composite cold-formed encased steel beam with protruded link can increase the value of moment and shear capacities compared to the reinforced concrete beam and composite steel beam. In conclusion, this study shows that the effect of the protruded link can enhance the moment and shear capacities of the composite coldformed encased steel beam.
format Thesis
qualification_level Master's degree
author Buhari, Suffian
author_facet Buhari, Suffian
author_sort Buhari, Suffian
title Design behaviour of cold-formed steel encased composite beam with protruded link
title_short Design behaviour of cold-formed steel encased composite beam with protruded link
title_full Design behaviour of cold-formed steel encased composite beam with protruded link
title_fullStr Design behaviour of cold-formed steel encased composite beam with protruded link
title_full_unstemmed Design behaviour of cold-formed steel encased composite beam with protruded link
title_sort design behaviour of cold-formed steel encased composite beam with protruded link
granting_institution Universiti Teknologi Malaysia, Faculty of Civil Engineering
granting_department Faculty of Civil Engineering
publishDate 2018
url http://eprints.utm.my/id/eprint/79049/1/SuffianBuhariMFKA2018.pdf
_version_ 1747818134542221312