Building condition assessment on Datin Seri Endon residential college

Building Condition Assessment (BCA) to determine the building deficiency information and can plan the suitable future maintenance or repair requirements for the college building at University Technology Malaysia (UTM). This activity is also important in monitoring building maintenance to maintain th...

Full description

Saved in:
Bibliographic Details
Main Author: Ibrahim, Izzuain
Format: Thesis
Language:English
Published: 2019
Subjects:
Online Access:http://eprints.utm.my/id/eprint/81038/1/IzzuainIbrahimMSKA2019.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.81038
record_format uketd_dc
spelling my-utm-ep.810382019-07-24T03:06:17Z Building condition assessment on Datin Seri Endon residential college 2019-01 Ibrahim, Izzuain TA Engineering (General). Civil engineering (General) Building Condition Assessment (BCA) to determine the building deficiency information and can plan the suitable future maintenance or repair requirements for the college building at University Technology Malaysia (UTM). This activity is also important in monitoring building maintenance to maintain the appearance and performance of the building. It needs to be preserved to ensure the value and life cycle of a building. This study relates to the problem of building structure in college buildings at University Technology Malaysia and the overall rating obtained for a building. In this case study, it only focuses on college buildings at UTM namely Datin Seri Endon College (KDSE). The main objective of this study is to determine the building that has problems in the building structure in the point view of the block occupants. This is done by distributing questionnaires to students about their room and toilet. Furthermore, for the second objective is to determine the defect rating on the structure and surrounding of the building to provide maintenance methods. Therefore, to get the data, it is necessary to conduct visual inspection activities on the site by taking pictures, taking notes, drawing and retrieving information from people living in the building. Subsequently, the data provided will summarize the actual situation and can handle future building maintenance. Based on this study, the W3 block was selected to run BCA after being surveyed from the survey. Even the rating on the building after the BCA shows that the building is still in good condition and requires minimal maintenance only on a single place. In the shell, this activity is very important for determining rating on buildings in colleges or other buildings. 2019-01 Thesis http://eprints.utm.my/id/eprint/81038/ http://eprints.utm.my/id/eprint/81038/1/IzzuainIbrahimMSKA2019.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:125179 masters Universiti Teknologi Malaysia, Faculty of Engineering - School of Civil Engineering Faculty of Engineering - School of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Ibrahim, Izzuain
Building condition assessment on Datin Seri Endon residential college
description Building Condition Assessment (BCA) to determine the building deficiency information and can plan the suitable future maintenance or repair requirements for the college building at University Technology Malaysia (UTM). This activity is also important in monitoring building maintenance to maintain the appearance and performance of the building. It needs to be preserved to ensure the value and life cycle of a building. This study relates to the problem of building structure in college buildings at University Technology Malaysia and the overall rating obtained for a building. In this case study, it only focuses on college buildings at UTM namely Datin Seri Endon College (KDSE). The main objective of this study is to determine the building that has problems in the building structure in the point view of the block occupants. This is done by distributing questionnaires to students about their room and toilet. Furthermore, for the second objective is to determine the defect rating on the structure and surrounding of the building to provide maintenance methods. Therefore, to get the data, it is necessary to conduct visual inspection activities on the site by taking pictures, taking notes, drawing and retrieving information from people living in the building. Subsequently, the data provided will summarize the actual situation and can handle future building maintenance. Based on this study, the W3 block was selected to run BCA after being surveyed from the survey. Even the rating on the building after the BCA shows that the building is still in good condition and requires minimal maintenance only on a single place. In the shell, this activity is very important for determining rating on buildings in colleges or other buildings.
format Thesis
qualification_level Master's degree
author Ibrahim, Izzuain
author_facet Ibrahim, Izzuain
author_sort Ibrahim, Izzuain
title Building condition assessment on Datin Seri Endon residential college
title_short Building condition assessment on Datin Seri Endon residential college
title_full Building condition assessment on Datin Seri Endon residential college
title_fullStr Building condition assessment on Datin Seri Endon residential college
title_full_unstemmed Building condition assessment on Datin Seri Endon residential college
title_sort building condition assessment on datin seri endon residential college
granting_institution Universiti Teknologi Malaysia, Faculty of Engineering - School of Civil Engineering
granting_department Faculty of Engineering - School of Civil Engineering
publishDate 2019
url http://eprints.utm.my/id/eprint/81038/1/IzzuainIbrahimMSKA2019.pdf
_version_ 1747818297839058944