Slope stability assessment of remedial measures adjacent to transmission tower

Slope stability analysis has received an increased attention in construction and development to ensure public safety and avoid economic loss. A high and steep soil slope failure had occurred on the slope adjacent to a newly built transmission tower in Murum, Sarawak. An effective slope remedial meas...

Full description

Saved in:
Bibliographic Details
Main Author: Yvonne, Pui
Format: Thesis
Language:English
Published: 2019
Subjects:
Online Access:http://eprints.utm.my/id/eprint/81172/1/YVonnePuiMSKA2019.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.81172
record_format uketd_dc
spelling my-utm-ep.811722019-07-24T03:35:09Z Slope stability assessment of remedial measures adjacent to transmission tower 2019-01 Yvonne, Pui TA Engineering (General). Civil engineering (General) Slope stability analysis has received an increased attention in construction and development to ensure public safety and avoid economic loss. A high and steep soil slope failure had occurred on the slope adjacent to a newly built transmission tower in Murum, Sarawak. An effective slope remedial measure is demanded to protect the transmission tower. This paper presented the slope stability assessment conducted using a well-established Finite Element Method computer software, i.e. “PLAXIS 2D” and “PLAXIS 3D”. Two remedial works alternatives had been proposed, which including retaining wall and secant bored pile. The slope stability of each remedial works was assessed in term of factor of safety (FOS). The impact of the material model on FOS was assessed using both Mohr-Coulomb model (MC) and Hardening Soil model (HS). Topography, laboratory and field data were obtained to simulate the actual slope failure. The slope stability assessment conducted found that the most effective remedial work is secant bored pile (SBP) to prevent soil movement. FOS obtained from PLAXIS 3D was more conservative in complex geometry. Material model did not significanty impact FOS. FOS of HS model was slightly lower than MC model. The remedial measures were assessed with respect to the slope stability only which it did not consider the factor of construction cost. 2019-01 Thesis http://eprints.utm.my/id/eprint/81172/ http://eprints.utm.my/id/eprint/81172/1/YVonnePuiMSKA2019.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:125183 masters Universiti Teknologi Malaysia, Faculty of Engineering - School of Civil Engineering Faculty of Engineering - School of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Yvonne, Pui
Slope stability assessment of remedial measures adjacent to transmission tower
description Slope stability analysis has received an increased attention in construction and development to ensure public safety and avoid economic loss. A high and steep soil slope failure had occurred on the slope adjacent to a newly built transmission tower in Murum, Sarawak. An effective slope remedial measure is demanded to protect the transmission tower. This paper presented the slope stability assessment conducted using a well-established Finite Element Method computer software, i.e. “PLAXIS 2D” and “PLAXIS 3D”. Two remedial works alternatives had been proposed, which including retaining wall and secant bored pile. The slope stability of each remedial works was assessed in term of factor of safety (FOS). The impact of the material model on FOS was assessed using both Mohr-Coulomb model (MC) and Hardening Soil model (HS). Topography, laboratory and field data were obtained to simulate the actual slope failure. The slope stability assessment conducted found that the most effective remedial work is secant bored pile (SBP) to prevent soil movement. FOS obtained from PLAXIS 3D was more conservative in complex geometry. Material model did not significanty impact FOS. FOS of HS model was slightly lower than MC model. The remedial measures were assessed with respect to the slope stability only which it did not consider the factor of construction cost.
format Thesis
qualification_level Master's degree
author Yvonne, Pui
author_facet Yvonne, Pui
author_sort Yvonne, Pui
title Slope stability assessment of remedial measures adjacent to transmission tower
title_short Slope stability assessment of remedial measures adjacent to transmission tower
title_full Slope stability assessment of remedial measures adjacent to transmission tower
title_fullStr Slope stability assessment of remedial measures adjacent to transmission tower
title_full_unstemmed Slope stability assessment of remedial measures adjacent to transmission tower
title_sort slope stability assessment of remedial measures adjacent to transmission tower
granting_institution Universiti Teknologi Malaysia, Faculty of Engineering - School of Civil Engineering
granting_department Faculty of Engineering - School of Civil Engineering
publishDate 2019
url http://eprints.utm.my/id/eprint/81172/1/YVonnePuiMSKA2019.pdf
_version_ 1747818313570844672