Shear reinforcement systems in rectangular reinforced concrete beams

Shear failure in beams is characterised by diagonal cracks in the shear span or near support. Consequently, any form of well anchored bar placed to cross these cracks will be able to carry shear to some extent. This project report presents the results of a study in which the development and applicat...

Full description

Saved in:
Bibliographic Details
Main Author: Ullah Khan, Saif
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:http://eprints.utm.my/id/eprint/91968/1/SaifUllahKhanMSKA2020.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.91968
record_format uketd_dc
spelling my-utm-ep.919682021-08-09T08:46:39Z Shear reinforcement systems in rectangular reinforced concrete beams 2020 Ullah Khan, Saif TA Engineering (General). Civil engineering (General) Shear failure in beams is characterised by diagonal cracks in the shear span or near support. Consequently, any form of well anchored bar placed to cross these cracks will be able to carry shear to some extent. This project report presents the results of a study in which the development and application of various types of shear reinforcement for the design of reinforced concrete beams were reviewed and discussed. The structural concept of these reinforcement and the behaviour of beams containing them were investigated and compared. The results indicate that the conventional vertical links is still the sole type of shear reinforcement preferred and applied by designers is almost all construction works. Although the bent-up bars had been used before, it has not been adopted since the last fifty years or so. This perhaps due to the unavailability of sufficient number of mid-span reinforcement to be extended and bent-up near the support. Alternative systems of shear reinforcement have also been tested namely the independent bent-up bars which configuration has later been improved and renamed the welded inclined bars, inclined links, independent horizontal bars and the swimmer bars. Of these the welded inclined bars proved to have relatively good shear resistance. Furthermore, since it is in the form of vertical longitudinal sheets tied to the top and bottom reinforcement, installation in beams is more practical. 2020 Thesis http://eprints.utm.my/id/eprint/91968/ http://eprints.utm.my/id/eprint/91968/1/SaifUllahKhanMSKA2020.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:138789 masters Universiti Teknologi Malaysia Faculty of Engineering - School of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Ullah Khan, Saif
Shear reinforcement systems in rectangular reinforced concrete beams
description Shear failure in beams is characterised by diagonal cracks in the shear span or near support. Consequently, any form of well anchored bar placed to cross these cracks will be able to carry shear to some extent. This project report presents the results of a study in which the development and application of various types of shear reinforcement for the design of reinforced concrete beams were reviewed and discussed. The structural concept of these reinforcement and the behaviour of beams containing them were investigated and compared. The results indicate that the conventional vertical links is still the sole type of shear reinforcement preferred and applied by designers is almost all construction works. Although the bent-up bars had been used before, it has not been adopted since the last fifty years or so. This perhaps due to the unavailability of sufficient number of mid-span reinforcement to be extended and bent-up near the support. Alternative systems of shear reinforcement have also been tested namely the independent bent-up bars which configuration has later been improved and renamed the welded inclined bars, inclined links, independent horizontal bars and the swimmer bars. Of these the welded inclined bars proved to have relatively good shear resistance. Furthermore, since it is in the form of vertical longitudinal sheets tied to the top and bottom reinforcement, installation in beams is more practical.
format Thesis
qualification_level Master's degree
author Ullah Khan, Saif
author_facet Ullah Khan, Saif
author_sort Ullah Khan, Saif
title Shear reinforcement systems in rectangular reinforced concrete beams
title_short Shear reinforcement systems in rectangular reinforced concrete beams
title_full Shear reinforcement systems in rectangular reinforced concrete beams
title_fullStr Shear reinforcement systems in rectangular reinforced concrete beams
title_full_unstemmed Shear reinforcement systems in rectangular reinforced concrete beams
title_sort shear reinforcement systems in rectangular reinforced concrete beams
granting_institution Universiti Teknologi Malaysia
granting_department Faculty of Engineering - School of Civil Engineering
publishDate 2020
url http://eprints.utm.my/id/eprint/91968/1/SaifUllahKhanMSKA2020.pdf
_version_ 1747818545090134016