Courtyard design variants for optimum indoor thermal performance of single storey fully-enclosed courtyard house in temperate-dry climate of Nigeria

Courtyard houses are common in Nigeria due to their numerous benefits, one of which is the ability of the courtyard to enhance the indoor thermal performance of the building. However, such benefit may not be achieved if the appropriate application of the Courtyard Design Variant (CDV) are unknown to...

Full description

Saved in:
Bibliographic Details
Main Author: Bulus, Markus
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:http://eprints.utm.my/id/eprint/96230/1/MarkusBulusPFABU2020.pdf_removed_removed.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.96230
record_format uketd_dc
spelling my-utm-ep.962302022-07-05T03:40:53Z Courtyard design variants for optimum indoor thermal performance of single storey fully-enclosed courtyard house in temperate-dry climate of Nigeria 2020 Bulus, Markus TX955-985 Building management Courtyard houses are common in Nigeria due to their numerous benefits, one of which is the ability of the courtyard to enhance the indoor thermal performance of the building. However, such benefit may not be achieved if the appropriate application of the Courtyard Design Variant (CDV) are unknown to the architect, even right from the design stage. While previous studies on CDVs in different climatic regions have been common, the same cannot be said about the temperate-dry climatic zone of Nigeria. Therefore, the aim of this study is to propose the most suitable CDV for optimum indoor thermal performance of single storey fully-enclosed courtyard houses in Nigerian temperate-dry climatic region. The optimum parameters of the CDVs namely Courtyard Shape Factors (CSFs), Courtyard Aspect Ratio (CAR), Orientation, Courtyard Overhang and Window-to-Wall Ratio (WWR) were established and their impacts on indoor thermal comfort were determined. The documentary survey and field measurement methods were used to determine the types of CSFs and CARs and their indoor thermal performances; while the simulation software -Integrated Environment Solution-Virtual Environment (IES-VE) - was used for the simulation experiment. The software was validated with a digital model of the selected case study courtyard house. This study reveals fourteen (14) types of CSFs and CARs. The smaller CSFs were found to have favourable indoor thermal performance than the larger ones. Four (4) optimum CSFs were established and the North-south orientation was established as the optimum of all CSFs models. The optimum courtyard overhang depth and WWR were also determined. This study concluded that smaller CSFs improve indoor thermal performance than the larger ones, while 1200mm courtyard overhang depth and WWR 16% have significant impact on indoor thermal comfort. Finally, CDVs for the design of thermally conducive single storey fully-enclosed courtyard houses in Nigerian temperate-dry climate was proposed. The significance of this study lies in its quest for a conducive courtyard house while the proposed CDV is its main contribution. 2020 Thesis http://eprints.utm.my/id/eprint/96230/ http://eprints.utm.my/id/eprint/96230/1/MarkusBulusPFABU2020.pdf_removed_removed.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:143209 phd doctoral Universiti Teknologi Malaysia Faculty of Built Environment & Surveying
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TX955-985 Building management
spellingShingle TX955-985 Building management
Bulus, Markus
Courtyard design variants for optimum indoor thermal performance of single storey fully-enclosed courtyard house in temperate-dry climate of Nigeria
description Courtyard houses are common in Nigeria due to their numerous benefits, one of which is the ability of the courtyard to enhance the indoor thermal performance of the building. However, such benefit may not be achieved if the appropriate application of the Courtyard Design Variant (CDV) are unknown to the architect, even right from the design stage. While previous studies on CDVs in different climatic regions have been common, the same cannot be said about the temperate-dry climatic zone of Nigeria. Therefore, the aim of this study is to propose the most suitable CDV for optimum indoor thermal performance of single storey fully-enclosed courtyard houses in Nigerian temperate-dry climatic region. The optimum parameters of the CDVs namely Courtyard Shape Factors (CSFs), Courtyard Aspect Ratio (CAR), Orientation, Courtyard Overhang and Window-to-Wall Ratio (WWR) were established and their impacts on indoor thermal comfort were determined. The documentary survey and field measurement methods were used to determine the types of CSFs and CARs and their indoor thermal performances; while the simulation software -Integrated Environment Solution-Virtual Environment (IES-VE) - was used for the simulation experiment. The software was validated with a digital model of the selected case study courtyard house. This study reveals fourteen (14) types of CSFs and CARs. The smaller CSFs were found to have favourable indoor thermal performance than the larger ones. Four (4) optimum CSFs were established and the North-south orientation was established as the optimum of all CSFs models. The optimum courtyard overhang depth and WWR were also determined. This study concluded that smaller CSFs improve indoor thermal performance than the larger ones, while 1200mm courtyard overhang depth and WWR 16% have significant impact on indoor thermal comfort. Finally, CDVs for the design of thermally conducive single storey fully-enclosed courtyard houses in Nigerian temperate-dry climate was proposed. The significance of this study lies in its quest for a conducive courtyard house while the proposed CDV is its main contribution.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Bulus, Markus
author_facet Bulus, Markus
author_sort Bulus, Markus
title Courtyard design variants for optimum indoor thermal performance of single storey fully-enclosed courtyard house in temperate-dry climate of Nigeria
title_short Courtyard design variants for optimum indoor thermal performance of single storey fully-enclosed courtyard house in temperate-dry climate of Nigeria
title_full Courtyard design variants for optimum indoor thermal performance of single storey fully-enclosed courtyard house in temperate-dry climate of Nigeria
title_fullStr Courtyard design variants for optimum indoor thermal performance of single storey fully-enclosed courtyard house in temperate-dry climate of Nigeria
title_full_unstemmed Courtyard design variants for optimum indoor thermal performance of single storey fully-enclosed courtyard house in temperate-dry climate of Nigeria
title_sort courtyard design variants for optimum indoor thermal performance of single storey fully-enclosed courtyard house in temperate-dry climate of nigeria
granting_institution Universiti Teknologi Malaysia
granting_department Faculty of Built Environment & Surveying
publishDate 2020
url http://eprints.utm.my/id/eprint/96230/1/MarkusBulusPFABU2020.pdf_removed_removed.pdf
_version_ 1747818650217218048