Magnetic Induction Tomography (MIT) simulation study for renal screening using different system frequencies and sizes of calcium oxalate

Nephrolithiasis is the process of forming stone in the kidney by crystallization. Due to the increasing prevalence of nephrolithiasis from time to time, medical institutions look for more advanced technology of medical imaging which can tackle the disadvantages of current medical imaging devices for...

Full description

Saved in:
Bibliographic Details
Main Author: Paulus, Thompson
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:http://eprints.utm.my/id/eprint/98280/1/ThompsonPaulusMSBME2020.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.98280
record_format uketd_dc
spelling my-utm-ep.982802022-12-04T10:02:45Z Magnetic Induction Tomography (MIT) simulation study for renal screening using different system frequencies and sizes of calcium oxalate 2020 Paulus, Thompson Q Science (General) Nephrolithiasis is the process of forming stone in the kidney by crystallization. Due to the increasing prevalence of nephrolithiasis from time to time, medical institutions look for more advanced technology of medical imaging which can tackle the disadvantages of current medical imaging devices for renal, which are non-invasive, free radiation and rapid use. The research encompassed the design simulation study of Magnetic Induction Tomography (MIT) system for renal screening by using COMSOL multiphysics. MIT is a soft field tomography and a non-contact imaging modality used to image the passive electromagnetic properties (conductivity, permittivity and permeability) by applying principle of electromagnetic induction. In this research, 8 copper trans-receiver coils were employed in the MIT system and fixed by the insulation belt. Meanwhile, geometric set-up of renal organ imitates the transverse section at renal level of human body. Sensor performance analysis of MIT system was done based on various frequency and radius of calcium oxalate inside kidneys. In conclusion, frequency and radius of calcium oxalate affect the sensitivity performance of MIT system and has inverse relationship with sensitivity performance. 2020 Thesis http://eprints.utm.my/id/eprint/98280/ http://eprints.utm.my/id/eprint/98280/1/ThompsonPaulusMSBME2020.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:144841 masters Universiti Teknologi Malaysia, Faculty of Engineering - School of Biomedical Engineering & Health Sciences Faculty of Engineering - School of Biomedical Engineering & Health Sciences
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic Q Science (General)
spellingShingle Q Science (General)
Paulus, Thompson
Magnetic Induction Tomography (MIT) simulation study for renal screening using different system frequencies and sizes of calcium oxalate
description Nephrolithiasis is the process of forming stone in the kidney by crystallization. Due to the increasing prevalence of nephrolithiasis from time to time, medical institutions look for more advanced technology of medical imaging which can tackle the disadvantages of current medical imaging devices for renal, which are non-invasive, free radiation and rapid use. The research encompassed the design simulation study of Magnetic Induction Tomography (MIT) system for renal screening by using COMSOL multiphysics. MIT is a soft field tomography and a non-contact imaging modality used to image the passive electromagnetic properties (conductivity, permittivity and permeability) by applying principle of electromagnetic induction. In this research, 8 copper trans-receiver coils were employed in the MIT system and fixed by the insulation belt. Meanwhile, geometric set-up of renal organ imitates the transverse section at renal level of human body. Sensor performance analysis of MIT system was done based on various frequency and radius of calcium oxalate inside kidneys. In conclusion, frequency and radius of calcium oxalate affect the sensitivity performance of MIT system and has inverse relationship with sensitivity performance.
format Thesis
qualification_level Master's degree
author Paulus, Thompson
author_facet Paulus, Thompson
author_sort Paulus, Thompson
title Magnetic Induction Tomography (MIT) simulation study for renal screening using different system frequencies and sizes of calcium oxalate
title_short Magnetic Induction Tomography (MIT) simulation study for renal screening using different system frequencies and sizes of calcium oxalate
title_full Magnetic Induction Tomography (MIT) simulation study for renal screening using different system frequencies and sizes of calcium oxalate
title_fullStr Magnetic Induction Tomography (MIT) simulation study for renal screening using different system frequencies and sizes of calcium oxalate
title_full_unstemmed Magnetic Induction Tomography (MIT) simulation study for renal screening using different system frequencies and sizes of calcium oxalate
title_sort magnetic induction tomography (mit) simulation study for renal screening using different system frequencies and sizes of calcium oxalate
granting_institution Universiti Teknologi Malaysia, Faculty of Engineering - School of Biomedical Engineering & Health Sciences
granting_department Faculty of Engineering - School of Biomedical Engineering & Health Sciences
publishDate 2020
url http://eprints.utm.my/id/eprint/98280/1/ThompsonPaulusMSBME2020.pdf
_version_ 1776100573394763776