Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane (IR)
A potentiometric membrane sensor has been developed and optimized based on [4](l)(2,3-diazabuta-l,3-diene)ferrocenophane as an ionophore for high selective determination of glutamate. The best performance was shown by a membrane with composition ratio of [4](l)(2,3-diazabuta-l,3-diene)ferrocenophane...
Saved in:
Main Author: | |
---|---|
Format: | thesis |
Language: | eng |
Published: |
2014
|
Subjects: | |
Online Access: | https://ir.upsi.edu.my/detailsg.php?det=1072 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:ir.upsi.edu.my:1072 |
---|---|
record_format |
uketd_dc |
spelling |
oai:ir.upsi.edu.my:10722020-02-27 Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane (IR) 2014 Norhafizah Bakeman QC Physics A potentiometric membrane sensor has been developed and optimized based on [4](l)(2,3-diazabuta-l,3-diene)ferrocenophane as an ionophore for high selective determination of glutamate. The best performance was shown by a membrane with composition ratio of [4](l)(2,3-diazabuta-l,3-diene)ferrocenophane (ionophore): PVC (binder): TEHP (plasticizer) at 9: 36: 55 (% w/w). The sensor works well in a linear range of 1.0 x 105 to 1.0 x 10"1 M glutamate with a Nemstian slope of 57.61.0 mV/decade and its detection limit is 7.95 x 10'6 M. The sensor shows working range within pH 6-10 at temperature 25.01 C and stable for a period of 3 months without any divergence in potentials with response time equal or less than 30 seconds. The selectivity coefficient values determined by mixed solution method, indicate a good selectivity for glutamate over a wide variety of other tested anions. 2014 thesis https://ir.upsi.edu.my/detailsg.php?det=1072 https://ir.upsi.edu.my/detailsg.php?det=1072 text eng closedAccess Masters Universiti Pendidikan Sultan Idris Fakulti Sains dan Matematik N/A |
institution |
Universiti Pendidikan Sultan Idris |
collection |
UPSI Digital Repository |
language |
eng |
topic |
QC Physics |
spellingShingle |
QC Physics Norhafizah Bakeman Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane (IR) |
description |
A potentiometric membrane sensor has been developed and optimized based on [4](l)(2,3-diazabuta-l,3-diene)ferrocenophane as an ionophore for high selective determination of glutamate. The best performance was shown by a membrane with composition ratio of [4](l)(2,3-diazabuta-l,3-diene)ferrocenophane (ionophore): PVC (binder): TEHP (plasticizer) at 9: 36: 55 (% w/w). The sensor works well in a linear range of 1.0 x 105 to 1.0 x 10"1 M glutamate with a Nemstian slope of 57.61.0 mV/decade and its detection limit is 7.95 x 10'6 M. The sensor shows working range within pH 6-10 at temperature 25.01 C and stable for a period of 3 months without any divergence in potentials with response time equal or less than 30 seconds. The selectivity coefficient values determined by mixed solution method, indicate a good selectivity for glutamate over a wide variety of other tested anions. |
format |
thesis |
qualification_name |
|
qualification_level |
Master's degree |
author |
Norhafizah Bakeman |
author_facet |
Norhafizah Bakeman |
author_sort |
Norhafizah Bakeman |
title |
Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane (IR) |
title_short |
Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane (IR) |
title_full |
Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane (IR) |
title_fullStr |
Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane (IR) |
title_full_unstemmed |
Entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane (IR) |
title_sort |
entiometric membrane sensor for determination of glutamate based on [4](1)(2,3-diazabuta-l,3- diene) ferrocenophane (ir) |
granting_institution |
Universiti Pendidikan Sultan Idris |
granting_department |
Fakulti Sains dan Matematik |
publishDate |
2014 |
url |
https://ir.upsi.edu.my/detailsg.php?det=1072 |
_version_ |
1747832937083043840 |