Potentiometric determination of salicylate by using zinc aluminium 4(2,4dichlorophenoxy) butyrate nanocomposite as ion selective electrode (IR)

This study describes the construction and characterisation of zinc aluminium layered double hydroxides-4(2,4-dichlorophenoxy)butyrate (Zn/Al-DPBA) nanocomposite membrane electrode for determination of salicylate. The best performance of the membrane electrode was shown by having compositions Zn/Al-D...

Full description

Saved in:
Bibliographic Details
Main Author: Norseyrihan Mohd Sohaimi
Format: thesis
Language:eng
Published: 2014
Subjects:
Online Access:https://ir.upsi.edu.my/detailsg.php?det=1671
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:ir.upsi.edu.my:1671
record_format uketd_dc
spelling oai:ir.upsi.edu.my:16712020-02-27 Potentiometric determination of salicylate by using zinc aluminium 4(2,4dichlorophenoxy) butyrate nanocomposite as ion selective electrode (IR) 2014 Norseyrihan Mohd Sohaimi QD Chemistry This study describes the construction and characterisation of zinc aluminium layered double hydroxides-4(2,4-dichlorophenoxy)butyrate (Zn/Al-DPBA) nanocomposite membrane electrode for determination of salicylate. The best performance of the membrane electrode was shown by having compositions Zn/Al-DPBA : PVC : 2-NPOE : NaTPB at 7 : 33 : 60 : 3 The sensitivity, selectivity, response time, working range and detection limit of the membrane sensor depends on the ionophore and the pH value of the solution. The best Nernstian slope for the membrane sensor is 58.8 1.0 mV per decade in the concentration range of 1.0 x 10-5 to 1.0 x 10-1 M with a detection limit of 3.9 x 10-6 M. The potentiometric response is independent of the pH of the solution in the pH range 4.0 to 12.0 at temperature 25.0 1.0 C. The proposed sensor was easy to develop, low cost, fast response time (11-35 seconds) and shows a good stability for at least 4 months without significant change in its performance characteristics. The selectivity coefficients were determined by the mixed solution method with fixed interference. Good selectivity towards salicylate ion in the presence of other ions was obtained. 2014 thesis https://ir.upsi.edu.my/detailsg.php?det=1671 https://ir.upsi.edu.my/detailsg.php?det=1671 text eng closedAccess Masters Universiti Pendidikan Sultan Idris Fakulti Sains dan Matematik N/A
institution Universiti Pendidikan Sultan Idris
collection UPSI Digital Repository
language eng
topic QD Chemistry
spellingShingle QD Chemistry
Norseyrihan Mohd Sohaimi
Potentiometric determination of salicylate by using zinc aluminium 4(2,4dichlorophenoxy) butyrate nanocomposite as ion selective electrode (IR)
description This study describes the construction and characterisation of zinc aluminium layered double hydroxides-4(2,4-dichlorophenoxy)butyrate (Zn/Al-DPBA) nanocomposite membrane electrode for determination of salicylate. The best performance of the membrane electrode was shown by having compositions Zn/Al-DPBA : PVC : 2-NPOE : NaTPB at 7 : 33 : 60 : 3 The sensitivity, selectivity, response time, working range and detection limit of the membrane sensor depends on the ionophore and the pH value of the solution. The best Nernstian slope for the membrane sensor is 58.8 1.0 mV per decade in the concentration range of 1.0 x 10-5 to 1.0 x 10-1 M with a detection limit of 3.9 x 10-6 M. The potentiometric response is independent of the pH of the solution in the pH range 4.0 to 12.0 at temperature 25.0 1.0 C. The proposed sensor was easy to develop, low cost, fast response time (11-35 seconds) and shows a good stability for at least 4 months without significant change in its performance characteristics. The selectivity coefficients were determined by the mixed solution method with fixed interference. Good selectivity towards salicylate ion in the presence of other ions was obtained.
format thesis
qualification_name
qualification_level Master's degree
author Norseyrihan Mohd Sohaimi
author_facet Norseyrihan Mohd Sohaimi
author_sort Norseyrihan Mohd Sohaimi
title Potentiometric determination of salicylate by using zinc aluminium 4(2,4dichlorophenoxy) butyrate nanocomposite as ion selective electrode (IR)
title_short Potentiometric determination of salicylate by using zinc aluminium 4(2,4dichlorophenoxy) butyrate nanocomposite as ion selective electrode (IR)
title_full Potentiometric determination of salicylate by using zinc aluminium 4(2,4dichlorophenoxy) butyrate nanocomposite as ion selective electrode (IR)
title_fullStr Potentiometric determination of salicylate by using zinc aluminium 4(2,4dichlorophenoxy) butyrate nanocomposite as ion selective electrode (IR)
title_full_unstemmed Potentiometric determination of salicylate by using zinc aluminium 4(2,4dichlorophenoxy) butyrate nanocomposite as ion selective electrode (IR)
title_sort potentiometric determination of salicylate by using zinc aluminium 4(2,4dichlorophenoxy) butyrate nanocomposite as ion selective electrode (ir)
granting_institution Universiti Pendidikan Sultan Idris
granting_department Fakulti Sains dan Matematik
publishDate 2014
url https://ir.upsi.edu.my/detailsg.php?det=1671
_version_ 1747832987309834240