Development of Argon fluoride (ArF) excimer laser ablation system and its diagnosis on optical materials

The growing interest in precise fabrication of micro and nano-structures such as optical components, sensors and devices make the conventional approach no longer satisfactory for micro scale structure. Excimer laser ablation is particularly well suited for material such as polymer because of their e...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd. Salleh, Mohd. Hazimin
Format: Thesis
Language:English
Published: 2004
Subjects:
Online Access:http://eprints.utm.my/id/eprint/4918/1/MohdHaziminMohdSallehMFS2004.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.4918
record_format uketd_dc
spelling my-utm-ep.49182018-02-28T06:50:01Z Development of Argon fluoride (ArF) excimer laser ablation system and its diagnosis on optical materials 2004-06 Mohd. Salleh, Mohd. Hazimin QC Physics The growing interest in precise fabrication of micro and nano-structures such as optical components, sensors and devices make the conventional approach no longer satisfactory for micro scale structure. Excimer laser ablation is particularly well suited for material such as polymer because of their excellent properties and ablation behavior. The objective of the project is to diagnose the ablation work for optical material. An ArF excimer laser was utilized as a source of energy. As a preliminary work, the laser was calibrated to determine the best performance of the laser beam. Various materials including thermal paper, high-density polyethylene (HDPE), plasticised polyvinyl chloride (PPVC) and polymethyl methacrylate (PMMA) material were employed as an ablating target. Each specimen was ablated with excimer laser which was operated at various parameter comprising of working distance, high voltage, repetition rate and number of pulses. The ablated materials were analysed by using Matrox Inspector 2.1, Video Test 5.0 and Ms Excel sofhvare. The changes in the refractive index of PMMA sample were analysed using Brewster angle. The results obtained showed that the ablation on these materials depended on working distance. A short working distance offered the best performance for ablation which was 30 cm, since less energy were lost during the propagation. The ablation work also depended on the high voltage in the range of 13 kV - 14kV, suitable for ablation process. The ablation work was also found to be independent with the repetition rate of the laser. Finally, the ablation was found sharply increased with respect to the number of pulses. The best performance for this study was found at 400 pulses. Two of the tested materials, PPVC and PMMA demonstrated good performance for the ablation work. The 3D image analysis, offer an estimation of depth of the ablation spot area. The refractive index of PMMA decreased from 1.46 to 1.23 in the range of 200 to 500 pulses. 2004-06 Thesis http://eprints.utm.my/id/eprint/4918/ http://eprints.utm.my/id/eprint/4918/1/MohdHaziminMohdSallehMFS2004.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Science Faculty of Science
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic QC Physics
spellingShingle QC Physics
Mohd. Salleh, Mohd. Hazimin
Development of Argon fluoride (ArF) excimer laser ablation system and its diagnosis on optical materials
description The growing interest in precise fabrication of micro and nano-structures such as optical components, sensors and devices make the conventional approach no longer satisfactory for micro scale structure. Excimer laser ablation is particularly well suited for material such as polymer because of their excellent properties and ablation behavior. The objective of the project is to diagnose the ablation work for optical material. An ArF excimer laser was utilized as a source of energy. As a preliminary work, the laser was calibrated to determine the best performance of the laser beam. Various materials including thermal paper, high-density polyethylene (HDPE), plasticised polyvinyl chloride (PPVC) and polymethyl methacrylate (PMMA) material were employed as an ablating target. Each specimen was ablated with excimer laser which was operated at various parameter comprising of working distance, high voltage, repetition rate and number of pulses. The ablated materials were analysed by using Matrox Inspector 2.1, Video Test 5.0 and Ms Excel sofhvare. The changes in the refractive index of PMMA sample were analysed using Brewster angle. The results obtained showed that the ablation on these materials depended on working distance. A short working distance offered the best performance for ablation which was 30 cm, since less energy were lost during the propagation. The ablation work also depended on the high voltage in the range of 13 kV - 14kV, suitable for ablation process. The ablation work was also found to be independent with the repetition rate of the laser. Finally, the ablation was found sharply increased with respect to the number of pulses. The best performance for this study was found at 400 pulses. Two of the tested materials, PPVC and PMMA demonstrated good performance for the ablation work. The 3D image analysis, offer an estimation of depth of the ablation spot area. The refractive index of PMMA decreased from 1.46 to 1.23 in the range of 200 to 500 pulses.
format Thesis
qualification_level Master's degree
author Mohd. Salleh, Mohd. Hazimin
author_facet Mohd. Salleh, Mohd. Hazimin
author_sort Mohd. Salleh, Mohd. Hazimin
title Development of Argon fluoride (ArF) excimer laser ablation system and its diagnosis on optical materials
title_short Development of Argon fluoride (ArF) excimer laser ablation system and its diagnosis on optical materials
title_full Development of Argon fluoride (ArF) excimer laser ablation system and its diagnosis on optical materials
title_fullStr Development of Argon fluoride (ArF) excimer laser ablation system and its diagnosis on optical materials
title_full_unstemmed Development of Argon fluoride (ArF) excimer laser ablation system and its diagnosis on optical materials
title_sort development of argon fluoride (arf) excimer laser ablation system and its diagnosis on optical materials
granting_institution Universiti Teknologi Malaysia, Faculty of Science
granting_department Faculty of Science
publishDate 2004
url http://eprints.utm.my/id/eprint/4918/1/MohdHaziminMohdSallehMFS2004.pdf
_version_ 1747814553938296832